background image

somfy.co.uk

W

e

 ar

e constantly seeking to develop and impr

ove our models, and ther

efor

e, 

we r

eserve the right to modify them at any time, in any way we may 

deem useful. Photos may dif

fer fr

om actual pr

oduct.

©SOMFY

. GMD030110 -SOMFY SAS, capital of

 

20,000,000, 

register

ed in Bonneville 303.970.230

Utilisable en UE, C

Usable in EU,C

Bruikbaar in EU, C

Utilizable en la UE, C

V

ersion 3 – 02/2008

SOMFY LTD
Moorfield Road
Yeadon
Leeds
West Yorkshire
LS19 7BN
Tel. 0113 391 3030
Fax. 0113 391 3010

MOTOR DRIVES FOR LEAF GATES

SGA

5000

SGA6000 gb.qxd  12/02/08  17:54  Page 1

Содержание SGA 5000

Страница 1: ...differ from actual product SOMFY GMD030110 SOMFY SAS capital of 20 000 000 registered in Bonneville 303 970 230 Utilisable en UE C Usable in EU C Bruikbaar in EU C Utilizable en la UE C Version 3 02 2...

Страница 2: ...14 18 13 11 16 5 12 17 15 6 7 19 1 2 3 4 9 8 10 SGA6000 gb qxd 12 02 08 17 54 Page 3...

Страница 3: ...1 17 9 8 10 18 15 16 14 13 11 12 5 6 1 2 7 9m 2 x 1 mm2 19 20 SGA6000 gb qxd 12 02 08 17 54 Page 5...

Страница 4: ...step installation 1 Preparing and drilling gateposts 12 2 Installing the motors 14 3 Mounting the arms 16 4 Electrical connections 20 5 Settings 23 Usage 29 Troubleshooting 31 Accessories 32 M10 x4 x4...

Страница 5: ...t may be used in the European Union and in Switzerland Before installing your product these instructions MUST be read carefully Follow each instruction to the letter and keep this document in your pos...

Страница 6: ...memorisable 16 Possible connections Orange LED output 24 V 10 W Area lighting output powered contact 500 W max Additional power outputs 24 Vdc 200 mA Backup battery input Yes Photoelectric cell input...

Страница 7: ...gs for the motor drive s arms must be mounted on the horizontal brackets of the leaves at about 1 3 of the height of the gate If there are no such brackets use backing plates approx 4 mm thick Checkin...

Страница 8: ...r the weight of vehicles passing over it ref 2400484 Provide a ducted connection between the two gateposts to wire the photocells 2 2 3 1 Bracket Motor M1 Motor M2 2 x 1 mm2 cable between motors 2 x 0...

Страница 9: ...asure dimension A Using the table below determine the maximum opening value of the leaves dimension B to determine the vertical positioning axis of the motors on the gateposts D Dimension A mm Maximum...

Страница 10: ...motors Position the motor by fastening it onto the lower threaded rods using the washers and nuts 1 Check that the motors are level Continue tightening if necessary 2 Position the motor on the gatepo...

Страница 11: ...ide of the arm making sure that their bosses are fully inserted into the arm s grooves 2 Installing the flexible ring in the arm Mounting the arms onto the motors Insert the flexible ring into the arm...

Страница 12: ...e fastening lug on the leaves then re install the arms into the fastening lug 5 8 Through the fastening lug mark the points on the leaf bracket where holes will be drilled 3 10 Check that the gate is...

Страница 13: ...and closes last Installing the grommets Connecting the two motors Connecting the antenna Connecting the mains power cord Locking the arms M2 M1 Blue Brown Brown Blue Blue Brown Blue Brown Case 1 Moto...

Страница 14: ...mplete opening only Both leaves systematically open com pletely with either a short or long press on the remote control Pedestrian or complete opening A single leaf opens to allow pedestrians access w...

Страница 15: ...ol your gate Place the remote on the crosshairs inscri bed on the casing Hold down the button to be memorised until the PROG LED blinks slowly the DANGER LED will come on while the button is being hel...

Страница 16: ...f the operations to programme the gate s travel path This must be a full cycle 2 complete and uninterrupted openings closings If it is interrupted the process is simply postponed and will resume the n...

Страница 17: ...omes on each time the gates are activated They go off automatically 2 minutes after movement has ended STOP Operation in sequential mode Complete opening Make a long press on the remote control Both l...

Страница 18: ...Check the transmitter battery Environmental disturbance such as electricity pylons or iron walls Provide for an outside antenna Other problems For all other problems or requests for information about...

Страница 19: ...ells are used to halt or reverse the gate s movement if an obstacle is detected A set of photocells may be installed Each set of photocells is comprised of a transmitting cell EC and a receiving cell...

Страница 20: ...Accessories Description and connections Digital code 2400581 Key switch 2400597 Intercom 2400463 blue brown white T1 C1 R1 V R3 T2 C2 R2 T3 C3 H P2 M P1 H E V blue brown white T1 C1 R1 V R3 T2 C2 R2...

Страница 21: ...576 Remote antenna 2400472 A wider range remote antenna may be used to replace the wire antenna It is to be placed atop the gatepost and must be unencumbered It is connected to the electronic box the...