![SOMFY S&SO-RS100 io Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/somfy/sandso-rs100-io/sandso-rs100-io_instructions-manual_1317672042.webp)
40
EN
Copyright © 2014 - 2016 Somfy SAS. All rights reserved.
Non contractual images.
2.1.4. Mounting the tube-drive assembly
1)
Fit and attach the tube-drive assembly to the end
support
f
and the drive support
g
:
Make sure that the tube-drive assembly is locked
in place on the end support. This prevents the tube-
drive assembly from coming out of the end support
fixing.
2)
Depending on the type of support, fit the retaining ring
h
in place.
2.2. WIRING
Respect Standard NF C 15-100 regarding the electrical installations.
Cables routed through a metal wall must be protected and insulated by sleeving or sheathing.
Secure the cables to prevent any contact with moving parts.
If the drive is used outdoors and if the power supply cable is of the H05-VVF type,
run
the
cable
in a UV-resistant duct, e.g. trunking.
The cable of the S&SO-RS100
io is removable. If it becomes damaged, replace it with
an
identical cable.
Leave the drive power supply cable accessible: it must be easily replaceable.
Always make a loop in the power supply cable
to
prevent water from entering the drive!
The S&SO-RS100
io is a Category II drive and has
no
earth wire.
-
Switch the power supply o
ff
.
-
Connect the drive according to the information provided
in the table below:
Cable
230 V
50 Hz
N
Blue
Neutral
L
Brown
Phase
2.3. SET
-
UP
This guide describes set-up using a Somfy Smoove io type io-homecontrol
®
local control point.
Identifying the steps to be performed
The settings for the end limits depend on the type of roller shutter:
1)
2)
h
f
g
1
1
1
OFF
230 V
50 Hz
N
L
N
L