5
Copyright © 2014 SOMFY ACTIVITES SA. All rights reserved.
EN
Rollixo io
Indicator light status
Prog
Photoelectric
cells
Diagnostics
Cell fault
Consequences
Opening ok
Closing by pressing and holding down
the button within sight of the door
Actions
Check that no obstacle is cutting across
the cell beam
Diagnostics
Obstacle detection
Consequences
Remove the obstacle by full automatic
opening
Actions
Check that no obstacle is cutting across
the cell beam.
If a fault is still present on your installation, please contact your installer.
6 - MAINTENANCE
6.1 Replacing the remote control battery
> Keytis
> Keygo
C
R 2
430
C
R 2
430
C
R 2
430
6.2 Replacing the safety edge transmitter battery
WARNING
Only use an AA 3V6 lithium battery (Somfy part number 1782078).
AA 1V5 alkaline batteries are not compatible.
4 screws
6.3 Replacing the integrated light bulb
[1]. Remove the integrated light bulb.
[2]. Replace the E14 - max. 1.4W - 230V LED bulb
WARNING
An LED bulb of the same type as that supplied (E14 - 1.4W - 230V) must be
used. Using another type of bulb may cause high dangerous overheating.
[1]
[2]
6.4 Checking the obstacle detection operation
Every month, check that the door reverses its movement when it encounters an
obstacle which is at least 50 mm high placed on the ground.
6.5
&KHFNLQJWKHVDIHW\GHYLFHVFHOOV
Check for correct operation every 6 months (see section 4.2).
7 - TECHNICAL DATA
GENERAL SPECIFICATIONS
Power supply
230 V - 50-60 Hz
Climatic operating conditions
- 20°C/+ 60°C - IP 20
Somfy radio frequency
io 868 - 870 MHz
< 25 mW
Number of storable remote controls
30