5. COMMISSIOnIng
Programming the first
Somfy
local control point
Pre-programming the
Somfy local control
point
Operation
c
or
d
Only one motor should be powered at a time.
Switch on the power and follow procedure "a" or "b",
depending on the blind's reaction:
a) The E.V.B. moves briefly
The end limits are set and no Somfy control point has
been programmed.
Go to the section entitled "Programming the first Somfy
local control point".
or
b) the E.V.b. does not move
Press the Up or Down button and follow procedure
"c" or "d" depending on the blind's
reaction:
c) the E.V.b. still does not move
The end limits are not set and no Somfy control point has
been programmed.
Go to the section entitled "Pre-programming the
Somfy local control point".
or
d) the E.V.b.is fully raised or lowered
The end limits are set and the Somfy control
point has been programmed.
Go to the section entitled "Operation".
5.2. Pre-programming the Somfy local control point
The guide only describes commissioning using a Telis MOD/VAR type Somfy local control point. For
commissioning using any other Somfy local control point, refer to the corresponding guide.
5.1. Identifying setting steps already completed
• Press the Up and Down buttons simultaneously.
The E.V.B. moves briefly; the Somfy local control point has
been pre-programmed into the motor.