5
Chronis RTS/RTS L
Chronis RTS/RTS L
is powered by two standard 1.5 V alkaline manganese batteries (Micro/AAA type). Battery life is approx.
3 years with an average of 4 commands per day. As the battery power decreases, the display contrast will fade. If the display
is illegible, the batteries must be changed.
Changing the batteries:
– Carefully remove the cover of the Chronis RTS/RTS L using a small screwdriver (for RTS L, first disconnect the light sensor).
– Slide the Chronis RTS/RTS L unit upwards out of the mounting plate.
– Change the dead batteries, which are located on the back of the Chronis RTS/RTS L unit. Observe the polarity specified on the unit!
– Please dispose of the dead batteries at an appropriate collection point.
After changing the batteries, the date and time must be reset. The switching time settings will be stored permanently.
6
Battery
The rSIP feature is usefull if you want your roller shutter or blind to got automatically to its intermediate position after a DOWN order given by the timer.
To enable the rsIP feature :
1. Press and maintain
+
+
until the display shows
2. Press
three times until the display shows
3. Press
to select the rsIP feature
4. Press
briefly to store and exit.
4.2
Setting operation mode
5.2
Controls ergonomics
4.2
Setting operation mode
5.3
rSIP feature
5.2.1 Control ergonomics for roller shutter operation
By pressing briefly the
or
push buttons, the shutter is activated in the corresponding direction.
By pressing briefly the
push button, the shutter stops.
Intermediate position
(If an intermediate position has been recorded in the receiver)
By pressing briefly the
push button while the shutter is already stopped, then the shutter will move and stop at the intermediate
position.
5.2.2 Control ergonomics for venetian blind operation
vbEU mode :
To drive the blind up to the end limits
➜
press and hold for more than 2 seconds the
or
push buttons.
To tilt the slats
➜
press briefly the
or
push buttons.
vbUS mode :
To drive the blind up to the end limits
➜
press briefly the
or
push buttons.
To tilt the slats
➜
press and hold the
or
push buttons.
Intermediate position
(If an intermediate position has been recorded in the receiver)
By pressing briefly the
push button while the shutter is already stopped, then the shutter will move and stop at the intermediate position.