![SOMFY GDK 700 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/somfy/gdk-700/gdk-700_installation-and-operating-manual_1317935060.webp)
26
EN
- GDK 700 installation and operating guide - SOMFY
4.1 Connecting the photoelectric cells (Ref.: 2400939)
4.2
Connecting the flashing orange light (Ref.: 2400596)
TX
RX
24 V
AC/DC
24 V
AC/DC
0 V
0 V
C
NO
If the cells are disconnected, it is essential to recreate the bridge between
terminals
“
1
” and “
2
”.
When positioning the cells, remove the bridge
created between
terminals
“
1
” and “
2
” of the
motor electronics.
EN
4
Accessories
The photoelectric cells allow the presence of an obstacle to be detected when opening/closing the door. An obstacle
placed between the cells will prevent the door from closing. if an obstacle is detected when the door is closing, the door
stops then reopens.
The integrated lighting is activated intermittently for 30 seconds.
The orange light is activated whenever the door moves, with a 2-second pre-warning before movement starts.
Switch the electrical power supply to the
motorisation
off before installing any peripheral.
DANGER
5