16
EN
- GDK 700 installation and operating guide - SOMFY
EN
2
Programming
#
Case 2:
Indicator light “B” flashes twice continuously => the motorisation is waiting for auto-programming
(case during installation).
3
x 2
•
Control the motor using
button
“
A
” (continuous
pressure) so that the transmission shuttle is engaged
on the carriage.
•
Maintain
button
“
A
” depressed to bring the door to
closed position.
NB: If button “A” is released, the shuttle stops. If button “A” is kept depressed again, the shuttle moves in the opposite
direction to the previous movement.
Release
button
“
A
” before the motor exerts too much pressure on the door.
4
x 2
x 2
•
Press
button
“
B
” to launch the
auto-programming cycle.
The door performs
a complete
Opening-Closing cycle.
If the auto-programming is
correct,
indicator light
“
B
”
goes out
.
If the auto-programming cycle was not
successful,
indicator light
“
B
”
flashes twice
.
In this case, start a new auto-programming
cycle using
button
“
B
”.
• During the auto-programming cycle:
If the door is moving, the movement is stopped and auto-programming is
interrupted if any of the buttons are pressed.
NB: The motor is again awaiting auto-programming (see case no.2 - figure 3).