EN
Dexxo Smart 800 io / Dexxo Smart 1000 io
16
Copyright
©
2021 SOMFY ACTIVITES SA. All rights reserved.
1.4.2
Risk prevention - motorisation for residential sliding
garage door
Zone 1
Zone 2
Zone 3
Zone 4
Zone 4
RISKS
SOLUTIONS
ZONE 1
Risk of crushing when clos-
ing
Obstacle detection built into
the motorisation.
Obstacle detection must be
confirmed as being compli-
ant with Appendix A of
standard EN 12 453.
For operation with auto-
matic closing, install photo-
electric cells.
ZONE 2
Risk of crushing with an ad-
jacent fixed section
Obstacle detection built into
the motorisation.
Obstacle detection must be
confirmed as being compli-
ant with Appendix A of
standard EN 12 453.
Protection by means of
mechanical protective solu-
tion (
) or by safety dis-
tances
ZONE 3
Risk of cutting or trapping
between the door panels in
gaps of between 8 mm and
25 mm
Eliminate all sticking points
and all sharp edges from the
surface of the door
Eliminate any gap ≥ 8 mm or
≤ 25 mm
ZONE 4
Risk of trapping between
the roller rails and bearings
Eliminate all sharp edges on
the guide rails
Eliminate any gap ≥ 8 mm
between the rails and the
bearings
Illustration
1: Mechanical protection
Illustration
2: Safety distance
1.5
Electrical installation
DANGER
The installation of the power supply must comply
with the standards in force in the country in which
the motorisation is installed, and must be carried
out by qualified personnel.
The power line must be exclusively reserved for the
motorisation and equipped with protection, com-
prising:
a 10 A fuse or breaker,
and a differential type device (30 mA).
An all-pole power supply cut-off device must be
provided.
It is recommended that a lightning conductor be in-
stalled (maximum residual voltage 2 kV).
Cable feed
Underground cables must be equipped with a protective
sheath with a sufficient diameter to contain the motor cable
and the accessories cables.
For overground cables, use a cable duct that will withstand
the weight of the vehicles (ref. 2400484).
1.6
Safety instructions relating to installation
WARNING
Before installing the motorisation, remove any un-
necessary cords or chains and deactivate any locking
device (bolt) which is not required for motorised
operation.
DANGER
Do not connect the motorisation to a power source
before installation is complete.
WARNING
Modifying any of the components in this kit or using
additional components not recommended in this
manual is strictly prohibited.
Monitor the door as it moves and keep people away from it
until installation is complete.
Содержание Dexxo Smart 1000 io
Страница 2: ......
Страница 45: ...Dexxo Smart 800 io Dexxo Smart 1000 io FR Copyright 2021 SOMFY ACTIVITES SA All rights reserved 45 ...
Страница 46: ...46 Copyright 2021 SOMFY ACTIVITES SA All rights reserved FR Dexxo Smart 800 io Dexxo Smart 1000 io ...
Страница 47: ...Dexxo Smart 800 io Dexxo Smart 1000 io FR Copyright 2021 SOMFY ACTIVITES SA All rights reserved 47 ...