EN
Dexxo Pro io
Copyright © 2015 SOMFY ACTIVITES SA. All rights reserved
5
Always reengage the motor drive mechanism before sending
another command to the motor drive unit.
4.2 Special operation
'HSHQGLQJRQWKHSHULSKHUDOVLQVWDOOHGDQGWKHRSHUDWLQJRSWLRQVVHWE\\RXU
installer, the motorisation may perform the following special operations:
> Using Telis, Situo or Composio
> Safety photoelectric cell operation
An obstacle detected between the cells will prevent the door from closing.
The door will stop and then completely or partially reopen (depending on the
setup selected during installation) when an obstacle is detected during the
close cycle.
7KHOLJKWZLOOÀDVKIRUVHFRQGVGXULQJWKLVSURFHVV
> Pedestrian door safety function
Opening a pedestrian door within the garage door will prevent the door from
moving.
7KHOLJKWZLOOÀDVKIRUVHFRQGVGXULQJWKLVSURFHVV
> Flashing orange light
7KHRUDQJHZDUQLQJOLJKWZLOOÀDVKHYHU\WLPHWKHGRRUPRYHV
A two second delay before the door starts to move can be selected during
installation.
> Remote lighting operation
The light comes on every time the motor drive unit is operated. The light will go
out one minute after the door stops moving. The time delay can be adjusted
during installation.
> Partial opening operation
If this option is selected:
- Pressing the remote control button programmed for partial opening causes
the door to open partially.
- Pressing the remote control button programmed for full opening causes the
door to open fully.
The partially open position will only operate from the closed position.
> Automatic closure mode operation
The door is automatically closed after a time delay set at the time of installation.
An additional command during this time will cancel the automatic closure and
the door will remain open.
The next command will close the door.
> Working from the back-up battery - Ref.9001001
,IDEDFNXSEDWWHU\LVLQVWDOOHGWKH'H[[R3URPRWRUZLOORSHUDWHZKHQDSRZHU
cut occurs.
The following conditions apply to operation:
-
'RRUVSHHGLVUHGXFHG
- The light will not come on.
- The safety devices are disabled.
%DWWHU\VSHFL¿FDWLRQV
-
(QGXUDQFH 7KH EDWWHU\ ZLOO ODVW IRU KRXUV ZLWK D PD[LPXP RI WR
operating cycles depending on the weight of the door.
- Recharging time: 48 hours.
- Service life prior to replacement: approx. three years.
To ensure optimum battery life, we recommend that the power to the motor
is switched off and the door is operated for a number of cycles using battery
power (three times a year).
> Forced operation mode
This function makes it possible to manipulate the door at any moment (loss of
remote control, photoelectric cell fault, etc.).
Remove the integrated light cover to access the “+” and “-” buttons.
'RRUVWDWLRQDU\
- press the “-” button to close it
- press the “+” button to open it.
'RRUPRYLQJSUHVVWKH³´RU³´EXWWRQWRVWRSWKHGRRU
> Operation after a power outage
If there is a power outage while the door is being opened, when the power is
restored the door should return to its opening stop; if the door does not reach
its opening stop, it cannot be closed.
Fully open the door using a memorised remote control. The door will open at
a reduced speed.
Allow the door to open to its "fully open" position.