manualshive.com logo in svg
background image

www.somfy.com

Interactive operating instructions

Ref. 

5129502A 

Chronis 

Smoove

 

UNO

Chronis 

Smoove

 

UNO S

Chronis 

Smoove

 

IB+

Soliris 

Smoove

 

UNO

Soliris 

Smoove

 

IB+

IB+

Chronis 
& Soliris 

Smoove

Содержание Chronis Smoove Series

Страница 1: ...www somfy com Interactive operating instructions Ref 5129502A Chronis Smoove UNO Chronis Smoove UNO S Chronis Smoove IB Soliris Smoove UNO Soliris Smoove IB IB Chronis Soliris Smoove...

Страница 2: ...s can be used in 3 ways in manual mode in automatic mode or in simulated presence mode The Soliris Smoove UNO and Soliris Smoove IB can be associated with an io homecontrol sun sensor and also wired s...

Страница 3: ...e simulation Automatic Summer Winter time Sunset in the control Sunrise in the control Auto from Optional settings and copy paste with a tool Timer Snow Rain Moon night Temperature Cloud Sun day Wind...

Страница 4: ...4 2 Time and Date 8 4 3 Type of End products 8 4 4 Runtime setup 9 4 5 Sun light Sensor 10 4 6 Wind Sensor Soliris versions 11 4 7 Rain Sensor Soliris versions 12 4 8 End of initial settings 12 5 MANU...

Страница 5: ...devices with IB input Important The settings on Chronis Soliris Smoove IB Smoove devices must be matched with the installed Smoove devices Current Smoove devices are fitted with an IB Bus input Previo...

Страница 6: ...igher menu In the Quick Menu back to main display 2 Moves end products upwards or downwards For setting the function value change operating the cursor For navigating between menus 3 Stop function when...

Страница 7: ...on see Chapter Quick Menu the activated function picture 1 as well as when a function is currently active picture 2 Stand by Mode After 3 minutes without touching the lighting on the display switches...

Страница 8: ...ext chapter Manual move command The basic settings are to be followed step by step To go to the next sep the configuration must be confirmed Use the soft key to go back to the previous step 4 1 Langua...

Страница 9: ...has been determined e g timed with a stopwatch 1 First set the minutes up to 5 and confirm 2 Then set the seconds and confirm Automatic When runtime of the product is unknown this can be set automatic...

Страница 10: ...vices provide the possibilities mentioned above See the selection table below Radio sensor Wired sensor Chronis Smoove Uno Chronis Smoove Uno S X Chronis Smoove IB X Soliris Smoove Uno X X Soliris Smo...

Страница 11: ...quires Select the sensor between wired or no sensor and confirm Note Not all devices provide the possibilities mentioned above See the selection table below Wired sensor Chronis Smoove Uno Chronis Smo...

Страница 12: ...ilities mentioned above See the selection table below Wired sensor Chronis Smoove Uno Chronis Smoove Uno S Chronis Smoove IB Soliris Smoove Uno X Soliris Smoove IB X With No sensor you can select a se...

Страница 13: ...netian blinds up A long press on the UP symbol moves the Venetian blinds up A short press on the DOWN symbol tilts the Venetian blinds down A long press on the DOWN symbol moves the Venetian blinds do...

Страница 14: ...is set as default In the display only the activated functions are shown Example the next time Cycle Time will appear in the display UP move command at 07 00 6 2 Auto from Current time 6 12 or 18 hour...

Страница 15: ...liday mode is displayed with a suitcase Example a fixed cycle time is set for 7 00 In Holiday mode the move commands are carried out randomly between 06 45 and 07 15 Further set functions such as sun...

Страница 16: ...me 4 can be carried out A timer command activates a move of the end products e g a downward move in the evening or an upward move in the morning As a rule the end products require two Cycle Times per...

Страница 17: ...mostly evenings when one does not wish to be seen my Position a position freely definable by the user also acces sible over the my soft key Position 2 not with Chronis Smoove Uno a second position de...

Страница 18: ...dually each day Setting Time Determine at what time the cycle times are activated 1 With the arrow select the following option and confirm 2 Select the time and confirm 3 Set the minutes and confirm S...

Страница 19: ...e radio sensor is applied 3 Select the radio sensor Both options Sensor Cosmic or Cosmic settings are displayed 4 Select the desired option in the Sensor Cosmic menu and confirm your selection Setting...

Страница 20: ...u can enter a difference time of 10 mins so that the Cycle Time is activated at 21h10 The difference time will be the same for each day Not before time with sunrise and Not after time with sunset the...

Страница 21: ...ducts move to the upper end position For test purposes the delay times can be shortened see Configuration in Professional Operating Mode Under Configuration menu select Sun function If you have alread...

Страница 22: ...om 1 to 10 Leave the menu with the soft key or ok menu button Position The target position is set to the value the end products should have after exceeding the threshold value Factory settings The Gla...

Страница 23: ...adio sensor and Pairing 2 Press on the program button of the Sunis WireFree io until the green LED lights up 3 Confirm Start The following message appears Searching for wireless sun sensor After a sho...

Страница 24: ...ction Configuration and confirm Radio sensor 2 Select Share key 3 Confirm Start The following message appears Wating for key sharing 4 Device 2 Go directly to Configuration menu Sun Function Configura...

Страница 25: ...delay the end products move to the preset position The sun symbol and the desired position are displayed during the move Subsequently the sun symbol appears again but smaller If the threshold value is...

Страница 26: ...nual operation sun automatic and the timer are then all released again Warning The Wind Function must be activated deliberately Under Configuration menu select Wind Function The following options are...

Страница 27: ...tton Configuration of the Wind sensor The wind sensor can be configured again 1 Select between the wired sensor and no sensor 2 Confirm your selection Display of the Wind Function on screen When the f...

Страница 28: ...g options are available If you have selected No sensor at start up you will be guided automatically to sensor configuration see Back to Configuration of the rain sensor Switching ON OFF You can switch...

Страница 29: ...Confirm your selection Display of the Rain Function on screen When the function is set and switched on Sensor s enabled is displayed Press on the Back arrow The rain symbol appears As soon as the rain...

Страница 30: ...ation menu select Configuration Language See Language Time See Time and Date Date See Time and Date User mode setup The User mode is set by default on Normal In the professional mode all further optio...

Страница 31: ...ou can set the brightness and contrast of the display Confirm the menu Display Brightness 1 With the arrow change the current value between 1 and 10 2 Select and confirm your preference Contrast 1 Wit...

Страница 32: ...See Runtime setup End Product See Type of End products Service Factory Settings The device can be reset to the factory state 1 Confirm this function 2 Confirm your selection Onconfirmation thefollowin...

Страница 33: ...he position 1 Set the position of the end products in percent 0 top 100 bottom 2 Confirm Tilt Note Only with Venetian blinds Under Glare protection tilt set you can set the angle 1 Settheangleinsecond...

Страница 34: ...e initialized with certain parameter settings such as Runtime The initialization ensures that the IB Smoove devices are connected together with the Chronis Soliris Smoove IB on the IB channel 1 Under...

Страница 35: ...ould be assigned Defining the Assignment 1 Confirm the Add device option then Start The LED on the Smoove Uno IB lights up alternatingly in green orange and red to show that the device is currently in...

Страница 36: ...always taken into account with manual operation 3 Confirm and select the zone to be operated You can now set off a move command in this zone only Note When a move command is set off the zone appears...

Страница 37: ...mmediately setoffamechanicalmove wake uptime Dependingonthemanufacturer this time can vary between 0 3 and 0 7 secs With Somfy WT motors this time is set generally 0 3 secs 1 Confirm this function 2 S...

Страница 38: ...to read the current version 2 Press on the button or on the ok menu button to exit the menu again Number of counter up or counter down movements 1 Confirm the corresponding option to read the number o...

Страница 39: ...C Protection type IP20 Protection class II Relays 230V AC 3A cos 0 9 Storage temperature 10 C 65 C Display 17 mm x 35 mm backlit Somfy hereby declares that the radio equipment covered by these instruc...

Страница 40: ...Somfy SAS 50 avenue du Nouveau Monde F 74300 CLUSES FRANCE www somfy com Somfy SAS capital 20 000 000 Euros RCS Annecy 303 970 230 11 2016...

Отзывы: