background image

The 4 motors can be moved to one or two selected intermediate positions. The recording and the calling-up of an intermediate position
can only be carried out by activating a connected “IP key” (see wiring diagram).
The first intermediate position is recorded from the upper end limit position of the system (shutter/awning up).
The second intermediate position is recorded from the lower end limit position of the system (shutter/awning down).

- Move the shutter/awning to the upper end limit position with the local switch.
- Press simultaneously the DOWN key and the “IP key” on the local switch (for approx. 2 seconds) until the shutter/awning moves downwards.
- Stop the shutter/awning at the desired position which is to be the intermediate position from the upper end limit position,by pressing: 

Simultaneously the up and down keys
or the IP key

- The intermediate position can be adjusted with the local switch.
- Press and hold the “IP key” for at least 2 seconds 

the intermediate position from the upper end limit position has been registered.

4.1 Recording the intermediate position from the upper end limit position

Upper end limit position

Lower end limit position

Intermediate position

- Move the shutter/awning downwards to the lower end limit position with the local switch.
- Press simultaneously the UP key and the “IP key” on the local switch (for approx. 2 seconds) until the shutter/awning moves upwards.
- Stop the shutter/awning at the desired position which is to be the intermediate position from the lower end limit position, by pressing: 

Simultaneously the up and down keys
or the IP key

- The intermediate position can be adjusted with the local switch.
- Press and hold the “IP key” for at least 2 seconds 

the intermediate position from the lower end limit position has been registered.

- When the 4 shutters/awnings are at the upper or lower end limit position, press briefly (less than 2 sec.) the “IP key”.

the shutters/awnings move to the recorded intermediate position.

4.3 Calling up a recorded intermediate position

4.2 Recording the intermediate position from the lower end limit position

- Move the 4 shutters/awnings to the intermediate position.
- Press the “IP key” for at least 10 seconds 

the intermediate position has been deleted.

4.4 Deleting a recorded intermediate position

All 4 motors can be moved to a selected intermediate position with a slat angle. The intermediate position is recorded from the upper end
position. The slat angle can also be called up at any time after a DOWN command has been activated, whatever the position of the blinds.
The recording and the calling-up of the intermediate position can only be carried out by activating a connected “IP key” (see wiring dia-
gram).

4

Intermediate position 

With roller shutters and awnings

5

Intermediate position 

With Venetian blinds

Содержание CD 1 x 4 P6

Страница 1: ...only be carried out by a qualified electrician respect the local electrical standard Disconnect all the connection wires which are to be fitted Take the necessary safety measures to prevent uninten tional reconnection Proper functioning can only be guaranteed by expert installation and sufficient power supply 1 1 Assembly Wiring CD 1 x 4 P6 for the DIN rail When fitting the CD 1 x 4 P6 board on 35...

Страница 2: ...ction open or bridge it Possibility to select two tilting functions European or US type European tilting mode Press briefly less than 0 8s the Venetian blind will be activated during the time of pressing tilting of the slats Press and hold more than 0 8s the Venetian blind will be activated during 3 minutes Up or Down control US tilting mode Press briefly less than 0 2s or continuous control longe...

Страница 3: ...e UP key and the IP key on the local switch for approx 2 seconds until the shutter awning moves upwards Stop the shutter awning at the desired position which is to be the intermediate position from the lower end limit position by pressing Simultaneously the up and down keys or the IP key The intermediate position can be adjusted with the local switch Press and hold the IP key for at least 2 second...

Страница 4: ...ded slat angle can be called up at any time after a local DOWN order i e blinds with closed slats by briefly pressing the IP key 5 3 Deleting the intermediate position The intermediate position and slat setting are deleted separately Deleting the intermediate position Move the 4 blinds to their programmed intermediate position Press the IP key for at least 10 seconds the intermediate position has ...

Отзывы: