EN
A
MOUNTING
[1]
Choose the optimal location: flat and large surface
[2]
Mount the IB+ 4 DC Motor Controller WM
[3]
Use cable tie!
[4]
Keep to minimum distance
B
CABLING
[1] Tool for all terminals
[2] Wiring diagram
[3]
Check the correct running direction of the end product
UP: the end product goes up ( C +
)
STOP: the end product stops ( C +
+
)
DOWN: the end product goes down ( C +
)
m
To close window press UP, to open window press DOWN.
[4]
Possible switches
1.
Smoove Origin IB, Ref. 1811272
2.
Double push button
[5]
Local control
One local push button can control motors on several Motor Controller.
C
COMMISSIONING AND OPERATING
[1] Reset/Prog button
Is the access to the basic configuration of the Motor Controller.
[2] Selection of the push button ergonomic
Local push button ergonomics and the type of end products to be
preselected:
• Screen mode (SCR)
• Venetian blind, European mode
• Venetian blind, US mode (default mode)
1.
To toggle between modes, press shortly the Reset / Prog button.
Repeat until the LED, according to the desired configuration, lights up.
2.
Save and exit
[3] Factory RESET
[4] Learn running time/length
1.
Drive screen to upper end limit
2.
Press Stop until screen drives down on its own
3.
Press shortly Stop when lower end limit is reached
[5] Learn and recall intermediate position (IP)
1.
Recording
2.
Recalling
Connection to …
Cable
Twisted pair
Max. length
Stripping length
Motors
Min.: 2 x 0.6 mm/22 AWG
Max.: 2 x 2.5 mm
2
/13 AWG
–
6 mm/0.24"
Switch
Min.: 3 x 0.6 mm/22 AWG
Max.: 3 x 2.5 mm
2
/13 AWG
Recommended
100 m/330 ft
6 mm/0.24"
IB+ bus
Min.: 4 x 0.6 mm/22 AWG
Max.: 4 x 1.5 mm
2
/15 AWG
Recommended
1000 m/3300 ft
6 mm/0.24"
24 V DC
Min.: 2 x 1.5 mm
2
/15 AWG
Max.: 2 x 2.5 mm
2
/13 AWG
–
10 m/33 ft
6 mm/0.24"
CABLE
CHARACTERISTICS
Supply voltage
24 V DC (min. 21.5 V - max. 28 V DC)
Power Supply
Regulated and short circuit proof power supply, certified and suitable for the connected motors
Stand-by current / Stand-by power (IEC 62301)
28 mA@24 V DC / 670 mW@24 V DC
Max. motor current consumption
4 x 2.5 A@24 V DC
Supply voltage of group control input
SELV, 16 V DC
Supply voltage of local push buttons
SELV, 16 V DC
Terminals
Spring connectors
Relay micro-gap
μ
Running time per output
Max. 5 minutes
Operating temperature
0 ° C ... + 45 ° C
Relative humidity
Max. 85 %
Material of housing
PC-ABS
Housing dimensions (w x h x d)
180 x 255 x 61 mm
Weight
690 g
Degree of protection
IP 20
Protection class
Pollution degree
2
Conformity
www.somfy.com/ce
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved collection point for recycling.
m
Control of non Somfy motors only on request and after approval by Somfy
animeo
IB+ 4 DC Motor Controller WM. Ref. 5138034A -
8/20
CORRECTION LOOP 2