Commissioning and standard use
20
EN
- SGS LINE installation and operating guide - SOMFY
EN
2
5
Position the opening stop in contact with the cylinder knob
then tighten the stops using an Allen key, diameter 3 (2
screws per stop).
Perform 2 full turns of the key aer contact.
6
Press button 1 on the remote control to close the gate
completely. The leaves close one aer the other.
2.3 Gate travel auto-programming
Check that the installation is switched on: the indicator light
flashes (twice).
Case 1: First commissioning of your motorisation
Press button 1 on the remote control to initiate a COMPLETE
opening motion of the gate.
When the gate is completely open, press button 1 on
the remote control again to initiate a COMPLETE closing
movement of the gate.
When the gate is completely closed, the indicator light on
the control unit should be CONTINUOUSLY LIT.
Case 2: You have just deleted the settings
Launch 4 full gate opening and closing movements.
Upon completion of the 4 movements, indicator light on the
control unit must be CONTINUOUSLY LIT.
The gate movements must not be interrupted (complete opening/closing).
If they are interrupted, programming will resume the next time the opening command is issued.
If indicator light flashes, relaunch auto-programming of the leaf travel (4 full opening and closing movements).
If the indicator light continues to flash, refer to “Diagnostics” page 31.
If the gate re-opens at the end of the closing movement, loosen and offset the gate leaf brackets slightly towards the centre of
the gate.
WARNING
Once installation is complete, it is essential to check that the obstacle detection complies with annex A of the standard EN 12 453.
Check before proceeding to the next step
Have you set the position of the opening stop on each motor?
1
2