10
EN
- SGS LINE installation and operating guide - SOMFY
EN
Electrical pre-equipment
Cables required
•
Power supply: 3 x 1.5 mm² cable or 3 x 2.5 mm² for outdoor use (type H07RN-F as minimum requirement).
•
Connection between the motors: 2 x 1 mm² cable; fit an IP 55 junction box to protect the connection between the cable leaving the motor
and the extension which goes to the control unit.
•
Linking of cells: 2 x 0.75 mm² cable;.
Cable feed
•
Underground cables must be equipped with a protective sheath with a sufficient diameter to contain all the cables.
•
Fit a 230 V electrical input as close as possible to the control unit.
Cables required
Details of the wiring are given in the section entitled “Wiring the accessories” page 22.
230V power
supply
Provision must be made for the power supply
cable to be fed through in accordance with
the electrical standards in force in the country
of use.
The cables are not supplied with the product.
Flexible ICT sheath
Motor cable
Extension to the control
unit
If a cable conduit cannot be made, use a cable grommet which will withstand the weight of vehicles (ref. 2400484).