42
8.1. Stop
The stop sequence of the unit is started by pressing the start/stop key for 3sec.
Until this phase has been completed, the display will show “
desactivação
" (Disabling).
The extractor will remain active until the fume temperature of 104ºF (40ºC) is reached, to
guarantee that all the material has been burnt.
8.2. Turning off the unit
The unit should only be disconnected after stoppage.
Make sure that the display indicates
“Off”
. If necessary, disconnect the power cable
from the mains.
8.3. Instructions for removing the side covers
8.3.1. Remove side covers
Raise the cover and pull backwards removing the upper and lower fixtures.
Do the opposite to assemble the unit.
Figure 24
– Removal of side covers
8.3.2. Pellet reservoir lid
The pellet reservoir is opened by sliding the bolt sideways
(
Erro! A origem da referência não foi encontrada.
-a, Figure 25
– Opening the lid) and
lifting the lid (
Erro! A origem da referência não foi encontrada.
-b).