92
7-36 String transmission
Note: The information in this chapter is closely related to 7-33 G1-G6 & C1-C3 & FN1 substitution
string setting.
Format of barcode data transmission:
Prefix
Code name
Preamble
Code ID
Code length
Code data
Code ID
Postamble
Suffix
Prefix transmission:
By setting Enable, prefix will be appended before the data transmitted.
Suffix transmission:
By setting Enable, suffix will be appended after the data is transmitted.
Code name transmission:
By setting Enable, code name will be transmitted before code data.
Preamble transmission:
By setting Enable, preamble will be appended before the data transmitted.
Postamble transmission:
By setting Enable, postamble will be appended after the data is transmitted.
Code ID transmission:
Code ID can be transmitted in the format of either Proprietary ID or AIM ID.
Refer to
1-2 Default setting for each barcode.
Code length transmission:
The length of code data string can be transmitted before the code data when
Enable is selected. The length is represented by a number with two digits.
Case conversion:
The characters within code data or the whole output string can be set in either upper
case or lower case.
FN1 substitution transmission:
The terminal supports a FN1 substitution feature for keyboard wedge,
USB and RS-232 interface. The replacement string of FN1 can be chosen by user (see
7-33 G1-G6 &
C1-C6 & FN1 substitution string setting
).
All-non-printable-character string transmission with string setting:
By setting enable, all string settings,
e.g. Preamble transmission or Insert G1 string setting, are active for an all-non-printable-character
string. Here a non-printable character means a character with ASCII value between 0x00 to 0x1F.
Transmit the first N data characters only:
The terminal supports to only transmit the first N data
characters of a barcode. The number of N can be set as a digit between 1 and 99.
Transmit the last N data characters only:
The terminal supports to only transmit the last N data
characters of a barcode. The number of N can be set as a digit between 1 and 99.
Содержание SX-DT-900
Страница 1: ...SX DT 900 Lightweight Data Terminal User Manual...
Страница 2: ......
Страница 15: ...9 1 6 Parts of the cradle Figure 1 4 Parts of the cradle Charging Green USB interface Firmware upgrade key...
Страница 17: ...11 Figure 2 2 Diagram of replacing the Lithium ion battery...
Страница 101: ...95 Home End Enter Insert Delete F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 Esc F11 F12...
Страница 108: ...102 14 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...