background image

04

Remote Control Battery Warning:

Only adults should handle the batteries. Do not allow a child to use the remote control unless the 
battery cover is securely attached to the battery compartment. All batteries must be disposed of 
at your local recycling point. 
Box Contents:
Please check that the following components are included within the box. If anything is missing or 
damaged, please contact the retailer and do not use the appliance until you have everything.

  Appliance with trailing lead.

  Remote control hand set.

  Optional flue collar.

  Instruction manual.

  This appliance can be used by children aged from 8 years and above and persons with reduced 

  physical, sensory or mental capabilities or lack of experience and knowledge if they have been 
  given instruction concerning use of the appliance in a safe way or are supervised and 
  understand the hazards involved.

  Children shall not play with the appliance.

  Cleaning and user maintenance shall not be carried out by children without supervision. 

  Children of less than 3 years should be kept away from the appliance unless continuously supervised. 

  Children aged from 3 years to 8 years shall only switch on/off the appliance provided that it 

  has been placed or installed in its intended normal operating position and they have been given 
  instruction concerning use of the appliance in a safe way or are supervised and understand the 
  hazards involved.

  Children aged over 3 and less than 8 years shall not plug in, regulate, clean nor maintain the 

  appliance.

  Children of any age should not be permitted to play with the appliance or its controls.

  If the supply cord is damaged, switch off the mains power at the wall socket immediately. It must 

  be replaced by the manufacturer, its service agent or a similarly qualified person in order to 
  avoid a hazard.

  Do not use the appliance in rooms with explosive gas (e.g. petrol) or while using inflammable glue 

  or solvent (e.g. when gluing or varnishing parquet floors, PVC etc.)

  Do not insert any objects into the appliance.

  This appliance must be connected to a 220/240V AC 50Hz supply.

Содержание SLE42s

Страница 1: ...4 108 EC The complete installation must be carried out in accordance with current Standards and Local Codes The instructions in this manual must be followed to ensure safe operation of the appliance I...

Страница 2: ...n Fuel Bed Brightness Operation Flame Brightness Operation Setting the Time and Day 24 Hour Clock Setting the Weekly Timer Thermal Safety Cut Out Light Emitting Diode Battery Replacement Remote Contro...

Страница 3: ...switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility CAUTION Some parts of this appliance around the heater grill can become very hot and ca...

Страница 4: ...nce shall not be carried out by children without supervision Children of less than 3 years should be kept away from the appliance unless continuously supervised Children aged from 3 years to 8 years s...

Страница 5: ...2 Fig 3 Fig 4 Locating the Unit Before commencing installation of the unit consideration should be given to the following 1 Position in the area to be heated central locations are usually best 2 Allow...

Страница 6: ...r Heater 12W Gross Weight kgs 45kg Efficiency Rating A Commissioning and Handover On completion of the installation Ensure that the operating instructions for the unit are left with the customer Ensur...

Страница 7: ...eat output elmax N A kW Type of heat output room temperature control select one At minimum heat output elmin N A kW single stage heat output and no room temperature control no In standby mode elSB 0 3...

Страница 8: ...inate when the fire is plugged in the wall socket switch is on and the manual on off switch is on The red light will remain illuminated for 10 seconds to show there is power to your fire Remote Contol...

Страница 9: ...above the room temperature for the heating function to operate Fig 23 Heater Operation Press the Heater button to select Full Heat 2000W and H02 with the flame symbol will be displayed see Fig 23 Pres...

Страница 10: ...can also be adjusted by pressing the Brightness button to select from the following levels see Fig 26 H High Maximum Setting C Central Intermediate Setting L Low Minimum Setting NOTE Icon flashes on...

Страница 11: ...on 2 Press and hold the Timer Mode button for two seconds to enter the timer settings 3 Press the Time Setting button to select the day to programme 4 The settings for the 1st ON OFF period 1 for Mon...

Страница 12: ...ty cut out is incorporated in the heater to prevent damage due to overheating This can happen if the heat outlet is restricted in any way The heater will switch on once the obstruction has been remove...

Страница 13: ...lluminated Check the flame effect and fuel bed lights have not been turned off from the remote Please refer to your retailer if your fire is not operating correctly after re reading these instructions...

Страница 14: ...s can be ordered from www solutionfires co uk or directly from a Solution Fire Retailer Items considered as consumable such as glass screens bulbs LED boards ceramic logs fuses and batteries which are...

Страница 15: ...2203011 3 Side Glass 2203016 4 Flame Screen 2203020 5 Blower and Heater Assembly 2203050 6 Power Supply Board 2203002 7 Main PCB Board 2203052 8 Fuel Bed LED 2203044 9 Flame LED 2203041 10 Synchronous...

Страница 16: ...Wiring Diagram www solutionfires co uk info solutionfires co uk Capital Fireplaces Units 12 17 Henlow Trading Est Henlow Bedfordshire SG16 6DS...

Отзывы: