6
Maintenance
2.1
-
To ensure the proper functioning of the system, it is recommended to carry out periodic
maintenance on the Ozone Generator.
2.2
-
Regularly inspect ozone supply tubing for cracks or wear. Make sure that is no water
present between the check valve and ozone generator
-
this indicates check valve failure. In
this case, replace the ozone check valve immediately.
Cautions
3.1
-
Follow the instructions in this Manual carefully.
3.2
-
Ensure that the equipment is placed in a location where it is at a level above the
maximum SPA water level. Use the fixing brackets and fix the equipment according this
manual.
3.3
-
You should not put the system into operation if the ozone generator is not well
supported. Ensure the installation of the equipment in a safe place, which protects it from
the weather, splashing water or excessive heat. When not in use, store the equipment in a
dry place at room temperature. Keep the equipment away from sources of water and/or
moisture.
3.4
-
Do not breathe ozone directly. Breathing ozone directly can be toxic, OSHA regulations
must be respected. Avoid sniffing or breathing directly over the equipment's air outlet.
3.5
-
Do not remove the screws or security seals from the equipment, in addition to violating
and voiding the warranty of the same, there is a risk of electric shock. Remember that this
equipment operates at high voltage even when disconnected from the power supply.
Maintenance Plan
Biweekly
Monthly
Semiannual
Annual
Check the Fan Dust Filter
X
Check the Pressure in the Circulation and
Mixing System
X
Perform the O
3
Generator Checkout by
Solution Ozone® Technicians
X
Table 2
-
Maintenance Plan
SSO
-
O3
-
##GPOOL01
-
User Manual (EN)
..
EN
Copyright @ 2020 Ozone Solution. All rights reserved. This document accompanies the O
3
System for SPAs. This document is subject to review.
Merely illustrative images.
Ver2/01
-
Ver.02
WARNING:
If you notice any ozone leakage, turn OFF the equipment's power supply immediately, leave
the space and only return after 30 minutes, so that all the ozone in the air is completely
dissipated.