4
1.5.2
-
Run tubing to the venturi (supplied with the Ozone Generator) or to an
appropriate vacuum source.
1.5.2.1
-
If the ozone generator is installed above the SPA Water Line, tubing may be
run directly to the venturi or to an appropriate vacuum source.
1.5.2.2
-
If the ozone generator is installed below the SPA Water Line, run tubing to a
point above the water line and back down (loop) to the venturi/vacuum source.
1.5.3
-
Secure all tubing connections with hose clamps.
Note: For circulation systems different from the one shown in image 2, contact your
SPA supplier for proper plug configuration.
1.6
-
Electrical installation (see image 3):
1.6.1
-
Verify there is no power to the SPA and connect the SSO
-
O3
-
SPA01 power cord
into the mating connector(s) on the SPA Control Box.
1.6.2
-
Where possible, route the SSO
-
O3
-
SPA01 power cord away from other electrical
lines. Avoid routing the power cord parallel to any low
-
voltage signal wires.
..
EN
SSO
-
O3
-
SPA01
-
User Manual (EN)
Image 2
-
Installation
Copyright @ 2020 Ozone Solution. All rights reserved. This document accompanies the O
3
System for SPAs. This document is subject to review.
Merely illustrative images.
Ver2/01
-
Ver.02
WARNING:
To reduce the risk of electrical shock, if the power cord is damaged, replace the
entire unit immediately.