MAINTENANCE INSTRUCTIONS
Regular monitoring of the machine is recommended. Before performing any maintenance, disconnect the machine
from the mains. Reduce the recommended maintenance intervals in situations of intensive use.
CONNECTION wITH AEROCOOL COOLING UNIT
The planned operation of the cooling unit is fully automatic. Check cooling unit operation mode. The advanced set-
ting parameter P.36 must be normal / automatic mode (nor).
Connect the cooling unit to the remote connector at the base of the power unit. It may be necessary to remove the
protective cover.
Please, make sure that once the cooling unit and power unit are interconnected, the connection is well secured to
avoid false contacts of the interconnecting cable.
During the first use, you may need to check the priming of the coolant in the circuit. The machine will try to do it auto-
matically. Alarm message 10 may appear during the process.
For more information on the operating modes of the cooling unit, please, see the description of advanced setting pa-
rameter P.36 in this manual and/or the Aerocool cooling unit manual.
Interval
Action
Weekly
Check the condition of wiring and external accessories.
Blow out the feed guide of the torch with compressed air and replace worn components.
Clean and tighten the electrical connections of the welding circuit
Clean the drive unit with compressed air.
Quarterly
Remove all rollers from the drive unit, clean to remove dust and dirt and lubricate slightly.
Annual
Carry out a complete inspection as specified by the standard EN-60974. See your dealer.
ATTENTION
The handling of internal parts of the machine should be performed only by qualified personnel.
There is a risk of electric shock on contact with live parts. You should NOT operate without the covers pro-
perly placed. Before accessing the interior of the machine, unplug it from the mains and wait at least 5 mi-
nutes before carrying out any maintenance.
ATTENTION
If your equipment configuration DOES NOT have a cooling unit, You must select disabled, "dis", in P.36 ad-
vanced setting parameter. Otherwise, Alarm 22 will be displayed
SOLTER