P.27
-
Not available in this model.
P.28
7
Arc-force
sensitivity for coated electrodes.
It allows adjustment of sensitivity to activate the arc-force mode. A high value delays
the activation of this feature. Lower values improve the transfer of material for alumi-
nium or stainless steel-coated electrodes.
P.29
65
Amperage preheating during TIG contact ignition.
P.30
-
Not available in this model.
P.31
-
Not available in this model.
P.32
-
Not available in this model.
P.33
-
Not available in this model.
P.34
-
Not available in this model.
P.35
3
Coolant circulation time at the end of a weld, in 10-second intervals.
P.36
Nor
Mode of operation of the cooling unit.
It is recommended to have the automatic mode selected at all times.
Nor
- Automatic mode (recommended).
For
- Forced mode. This can be used for a short period of less than 2 minutes to faci-
litate the task of priming the coolant circuit.
dis
–Disabled mode. Select this mode if an uncooled torch is going to be used. Re-
member to enable the automatic mode again when finish. DO NOT disable the cooler
if you are using a cooled torch as this could damage the torch.
P.37
-
Not available in this model.
P.38
-
Not available in this model.
P.39
-
Not available in this model.
P.40
-
Not available in this model.
P.41
-
Not available in this model.
P.42
-
Not available in this model.
P.43
-
Not available in this model.
P.44
-
Not available in this model.
P.45
-
Not available in this model.
P.46
1
1 is recommended to manage bead penetration depending on the energy of the arc,
or 0 to manage penetration depending on the amperage.
P.47
0
If enabled, it allows the penetration control a greater arc height variation. It is recom-
mended to keep it disabled to minimize welding defects.
P.48
-
Not available in this model.
P.49
-
Not available in this model.
P.50
-
Not available in this model.
P.51
-
Not available in this model.
P.52
-
Not available in this model.
P.53
-
Not available in this model.
P.54
-
Not available in this model.
P.55
-
Not available in this model.
P.56
-
Not available in this model.
P.57
50
Speed of wire threading under local control in 0.1m/min.
P.58
125%
Speed ratio between the winder motor and the torch motor.
P.59
5
Assistance supervision setting for MIG Arc-force in the event of disturbances.
P.60
12
Wire feed speed before starting the arc at 0.1m / min.