background image

CSW-M85 User’s Manual Ver. 1.6

 

 

Sollae Systems Co., Ltd. 

- 9 - 

http://www.sollae.co.kr

 

 

1.5.4  Pin assignment 

 

CON1/CON2 
CON1 and CON2 have headers of 2mm pitches. 

Table 1-1 CON1 

CON1 

Name 

Description 

Direction 

GND 

Ground 

SYS_RST#  System Reset (Active Low) 

IN 

ISP# 

ISP pin (to enter ISP mode) 

IN 

TCP# 

TCP connection state (Established - Low) 

OUT 

RXD 

UART IN 

IN 

TXD 

UART OUT 

OUT 

CTS 

UART CTS 

IN 

RTS 

UART RTS (RS232) 
UART TXDE(RS485) 

OUT 

DRXD 

Debugging port (UART IN) 

IN 

10 

DTXD 

Debugging port (UART OUT) 

OUT 

11 

LINK_Q# 

Link Quality 

IN 

12 

CONFIG#  Configuration mode / Factory Reset 

IN 

Table 1-2 CON2 

CON2 

Name 

Description 

Direction 

STS_LED 

Status LED 

OUT 

LINK_LED#  WLAN LINK LED (Established - Low) 

OUT 

RXD_LED#  WLAN RXD LED (Data Received - Low) 

OUT 

TXD_LED#  WLAN TXD LED (Data Transmitted - Low) 

OUT 

3.3V 

DC 3.3V IN 

IN 

NC 

This pin is Not Connected   

GND 

Ground 

USB_VBUS  (only for RF test) 

NC 

This pin is Not Connected 

10 

USB_D- 

USB_D- (only for RF test) 

IN/OUT 

11 

USB_D+ 

USB_D+ (only for RF test) 

IN/OUT 

12 

GND 

Ground 

 

 

Содержание CSW-M85

Страница 1: ...Sollae Systems Co Ltd http www sollae co kr Serial to Wi Fi module CSW M85 User s Manual Version 1 6...

Страница 2: ...or the package indicates that disposal of this unit after its lifecycle could harm the environment Do not dispose of the unit as unsorted municipal waste it should be brought to a specialized company...

Страница 3: ...ponents 11 2 Installation and Test 13 2 1 Background knowledge 13 2 1 1 Topology 13 2 1 2 Key terms 14 2 1 3 Authentication and Security 15 2 2 Installation 16 2 2 1 Making Wireless LAN link 16 2 2 2...

Страница 4: ...on Modes 32 5 1 TCP Server 32 5 1 1 Key parameters 32 5 1 2 Examples 33 5 2 TCP Client 36 5 2 1 Key parameters 36 5 2 2 Examples 37 5 3 AT Command 39 5 3 1 Key parameters 39 5 3 2 Examples 40 5 4 UDP...

Страница 5: ...Frame Interval 57 7 3 4 TCP Server Client mode 58 7 4 Additional Functions 59 7 4 1 Factory Reset 59 8 Checklist in Trouble 60 8 1 Searching problem with ezManager 60 8 2 Connection Problem over TCP I...

Страница 6: ...as short distance and hard maintenance CSW M85 is a module typed converter enables serial devices to support TCP IP communication through wireless LAN IEEE 802 11b g n CSW M85 carries out the convert...

Страница 7: ...network with a PC through an AP Figure 1 2 1 1 network with a PC through an AP Internet connection with a xDSL cable modem Figure 1 3 Internet connection with an xDSL cable modem 1 4 Components CSW M8...

Страница 8: ...S Compliant 1 5 2 Software Protocol TCP UDP IP ICMP ARP TELNET DHCP PPPoE DNS lookup DDNS Telnet COM Port Control Option RFC2217 WEP WPA PSK WPA2 PSK Diagnose Console port 115 200 N 8 1 Operation mode...

Страница 9: ...CSW M85 User s Manual Ver 1 6 Sollae Systems Co Ltd 8 http www sollae co kr 1 5 3 Dimension Top view Figure 1 4 top view Side Bottom view Figure 1 5 side bottom view...

Страница 10: ...S RS232 UART TXDE RS485 OUT 9 DRXD Debugging port UART IN IN 10 DTXD Debugging port UART OUT OUT 11 LINK_Q Link Quality IN 12 CONFIG Configuration mode Factory Reset IN Table 1 2 CON2 CON2 Name Descri...

Страница 11: ...C191GCT 1 2 CTS UART INTERFACE R1 330 J SYS_RST TXD_LED 3 3V ISP 3 3V TCP RTS TCP CONFIG F R OMU SE RPR O C E SS O R 3 3V ISP RF Test Port USB_D F R OMU SE RPR O C E SS O R D3 L C191GCT 1 2 D6 L C191G...

Страница 12: ...nection USB socket Only for RF Test Connector for supplying 5V DC power JP3 Jumper for connecting the Line driver for RS232 port Division ON OFF using RS232 using TTL Figure 1 8 jumper positions of JP...

Страница 13: ...nking when transmitting data to the network JP2 jumper for changing modes Mode 3 3V ISP GND Normal ISP Serial Configuration Less than 1 sec Figure 1 9 jumper positions of JP2 Console JP5 port for debu...

Страница 14: ...d has two network topologies Infrastructure and Ad hoc mode CSW M85 also supports WEP WPA PSK and WPA2 PSK for security 2 1 1 Topology Infrastructure mode In this mode every wireless LAN station commu...

Страница 15: ...LAN So every single station should have the same SSID to communicate in the network In the case of infrastructure mode you have to set the same SSID with the AP to CSW M85 Otherwise it won t communic...

Страница 16: ...i wireless connection It is an improvement on and is expected to replace the original Wi Fi security standard Wired Equivalent Privacy WEP There are two modes about the user authentication in WPA secu...

Страница 17: ...less LAN link is not automatically established when you connect the AP or wireless LAN adapter to your PC Wireless LAN parameters should be configured on CSW M85 Follow the steps below if you are a be...

Страница 18: ...rch the wireless network on your PC and try connecting your PC to the network 2 2 2 Setting Network Area These steps are for setting both CSW M85 and your PC to be located in the same network Only if...

Страница 19: ...CSW M85 User s Manual Ver 1 6 Sollae Systems Co Ltd 18 http www sollae co kr Figure 2 6 setting PC...

Страница 20: ...e below Keeping these values without any changes are highly recommended for the simple test Table 2 1 default values of major parameters Name Default values Network Local IP Address 10 1 0 1 Subnet Ma...

Страница 21: ...to the CSW M85 via LAN Figure 2 8 settings for TCP connection Select TCP Client Input correct IP address and port number of CSW M85 Click the Connect button In the case of TCP Server it will be Listen...

Страница 22: ...http www sollae co kr Confirm the TCP Connection and COM port status Figure 2 10 TCP Connected message Check the message if the TCP connection has been established well Figure 2 11 COM Port open mess...

Страница 23: ...sollae co kr Data transmission test Figure 2 12 successful data transmission Click Send data on the LAN part Check the data from has been shown Figure 2 13 WLAN RS232 Press Send data on the RS232 par...

Страница 24: ...nager Figure 3 1 initial appearance of ezManager 3 1 1 Configuration via WLAN Checklists Make sure the WLAN connection between your PC and CSW M85 If they are on the same network MAC Address search ca...

Страница 25: ...nfiguration mode By connecting the ISP pin to GND shortly between 20ms and 1 sec you can set the mode to Serial Configuration mode After this step read the setting via Serial tab on ezManager Procedur...

Страница 26: ...ameters of serial communication are needed to be set to the same values with your MCU Figure 3 5 setting the communication mode to the AT command Procedures Figure 3 6 configuration procedures with AT...

Страница 27: ...and name servers can be automatically designated using DHCP protocol In order to do so you should select Obtain an IP Automatically DHCP option on the ezManager You can set the address of DNS server...

Страница 28: ...s assigned automatically in PPPoE environment and you can set the address of DNS server manually or automatically Figure 3 8 obtain an IP automatically via PPPoE Procedures Choose Network tab Select t...

Страница 29: ...to make an account and create host names on the website of DynDNS before you use All about service usage of an account could be changed according to the policy of DynDNS Homepage of DynDNS http dyn co...

Страница 30: ...mode is for configuring environmental parameters through the serial port ISP mode This mode is only for changing firmware Link Quality Indication mode This mode is for indicating Wi Fi Received Signa...

Страница 31: ...ison of four communication modes Mode Protocol Connection Requirements about Modifying S W of serial devices Serial configuration Topology TCP Server TCP Passive N A N A 1 1 TCP Client Active N A N A...

Страница 32: ...configuration protocol please refer to the Serial Management Protocol document in Download Technical documents Basic and Common part category of our web site 4 6 ISP Mode 4 6 1 Upgrading Firmware ISP...

Страница 33: ...ent bytes you can handle the serial data of the serial buffer before a TCP connection is established Table 5 1 Event Byte Value Description 0 CSW M85 doesn t send the data Otherwise 512 or under CSW M...

Страница 34: ...tates M85 is listening to connection requests Remote host has sent a connection request SYN segment Processes of the connection The connection has been established Data communication is implemented on...

Страница 35: ...ach point Points States M85 is listening to connection requests Remote host has sent a connection request SYN segment Processes of the connection The connection has been established Data communication...

Страница 36: ...ime chart Table 5 4 states of each point Points States Data communication on both sides The last segment has arrived at the M85 for 5 seconds no data communication M85 has sent disconnection request F...

Страница 37: ...quest segment 0 right after M85 boots up Otherwise 512 or under Right after the bytes set to Event Byte have been received from the serial port 512 or under bytes are strongly recommended In addition...

Страница 38: ...t Points States Power has not been supplied yet M85 sends connection request segment right after it boots up processes of TCP connection The connection has been established data communication on both...

Страница 39: ...rt M85 sends connection request segment right after receiving 5 bytes processes of the TCP connection The connection has been established The data 1234567 has been transmitted to the remote host As yo...

Страница 40: ...PPE PPPoE AT PPE 1 ON CR PTO Timeout AT PTO 10 CR WCCT WLAN Topology AT WCCT 1 CR WSSID SSID AT SSID sollae CR WANT Antenna AT WANT 0 CR PWP Store setting AT PWP CR Related items with IP Address and L...

Страница 41: ...s of each points Points States configuring parameters with AT commands ATA command has arrived M85 is listening to TCP connection requests A remote host has sent SYN segment to M85 processes of TCP co...

Страница 42: ...rs and active connection Figure 5 7 time chart Table 5 11 states of each point Points States configuring parameters with AT commands M85 has sent a TCP connection request with the ATD command processe...

Страница 43: ...segment right after the ATH has arrived processes of TCP disconnection TCP connection has been terminated M85 sends NO CARRIER with disconnection CSW M85 changes the mode to AT command when receiving...

Страница 44: ...sends them as one block to the network The maximum value could be 1460 bytes Data Frame Data Frame means the time for gathering data to make one block Its unit is 10ms If there are no data from the s...

Страница 45: ...hart Table 5 13 states of each point Points States M85 is receiving data from the serial port M85 has sent 5 bytes as one block based on the Event byte Serial device is sending data 678 The data 678 h...

Страница 46: ...ss 0 None Peer Port 0 Figure 5 10 time chart Table 5 15 states of each point Points States Remote host 2 is sending data 123 to M85 M85 has set host 2 to its peer host M85 is sending ABC from the seri...

Страница 47: ...ownload the latest firmware file We upload it on our homepage if a new one is released Connecting the serial ports Connect serial port of CSW M85 to the PC s COM port with RS232 cross cable Run the pr...

Страница 48: ...Checking firmware file and Sending Figure 6 2 sending firmware file Check if the name and path of the firmware file are correct Click the Send button Request for reboot message will appear After reboo...

Страница 49: ...re 6 3 log in to CSW M85 via TELNET Following commands help you check states of CSW M85 Table 6 1 commands for checking states Command Option Description Usage st net Network Status lsh st net sio Ser...

Страница 50: ...www sollae co kr st uptime This command is for showing system uptime since M85 has booted up Figure 6 6 st uptime command sc This command is for disconnecting one of the current sessions Input session...

Страница 51: ...the window the status will be automatically updated in every second Figure 6 8 status window of ezManager FIRMWARE VERSION The name of model and the version of firmware are displayed here SYSTEM UPTIM...

Страница 52: ...et_rx The number of data which is received from the remote host sio_tx The number of data which is sent to the COM port ARP Table This part shows ARP table on CSW M85 When TCP connection is establishe...

Страница 53: ...A difference from TCP STATE is that users can terminate TCP connection When right click on a session a small pop up window is created Password This text box is activated when CSW M85 has a password I...

Страница 54: ...le 7 1 examples of defining allowed IP range IP Address Network Mask Allowed IP Address Range 10 1 0 1 255 0 0 0 10 1 0 1 10 255 255 254 10 1 0 1 255 255 255 0 10 1 0 1 10 1 0 254 192 168 1 4 255 255...

Страница 55: ...manufacturer Choosing Authentication and Encryption Methods Select WEP on the panel Figure 7 1 security settings Table 7 2 available values Parameter Available Values Encryption None WEP WPA Authentic...

Страница 56: ...et AP s parameters please refer to the manual or ask the manufacturer Choosing Authentication and Encryption Methods Select WPA on the panel Figure 7 3 security settings Setting WPA Key Figure 7 4 an...

Страница 57: ...C Address Sending MAC Address is a function that the CSW M85 sends its MAC address to the remote host right after a connection By using this function a server can identify multiple devices with the in...

Страница 58: ...the states are changed 7 3 2 Disable TCP Transmission Delay If you use this option CSW M85 sends the data from the serial port to Ethernet as quickly as possible 7 3 3 Data Frame Interval Before send...

Страница 59: ...on TCP client mode only In this mode you don t need to change the mode for switching active or passive TCP connection Note that the Event Byte option should be set to more than 1 If you want to get m...

Страница 60: ...ry default Using Factory Reset Connect pin 12 CONFIG of CON1 to GND input LOW signal Connect pin 3 of CON1 to GND input LOW signal over 3 seconds Factory Reset will be automatically implemented to def...

Страница 61: ...ower is supplied continually Connection with the wireless network Check if the wireless link is established After confirming that the status of LINK LED is ON check the list of wireless LAN devices on...

Страница 62: ...t send any reply from the request check the network environment Network Firewall In the case of networks which need strong security the access may be denied by their firewall Under this circumstance c...

Страница 63: ...each pin is right Pin assignment is listed on the Table 1 1 CON1 and Table 1 2 CON2 Using a cable you have to choose the right type of cable which is suitable for the device Setting parameters Check...

Страница 64: ...Refund Upon the customer s request to refund the product within two weeks after purchase Sollae Systems will refund the product 9 2 2 Free Repair Services For product failures occurring within one ye...

Страница 65: ...tions provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration is seve...

Страница 66: ...been updated Link Quality Indication function has been added Factory Reset has been added Caution about service using of DynDNS has been added The application circuit has been modified Roy LEE 2012 01...

Отзывы: