CSW-H80 User Manual Ver. 3.0
- 57 -
7.3.3 Data Frame Interval -
③
Before sending data from the serial port to Ethernet, ezTCP gathers data in the buffer. If
there is no data during the time configured in the [Data Frame Interval], ezTCP will send
data to the network. In case the value is set to 0, data will be sent immediately. The unit is
10ms and this is operated more accurately by checking [Disable TCP Transmission Delay]
option.
7.3.4 TX interval -
④
This option is for preventing data loss in the case that the serial device has very small
buffer size or doesn’t have a buffer. The range of the value could be from 0 to 25 and the
unit is duration of sending 1 byte. For example, if you set this value to 5, each byte will be
transferred with duration of sending 5 bytes.
7.3.5 TCP Server / Client mode -
⑤
This mode is available on TCP client mode only. In this mode, you don’t need to change
the mode for switching active or passive TCP connection. Note that the [Event Byte] option
should be set to 1 or lager value.
Refer to the [TCP Server/Client mode] document on our website for details.