9. Specifications
9. Specifications
.62.
.63.
Features
Quick connection plug
AC connection
Communication
Warranty
RS485, Optional:Wi-Fi, GPRS
5 years standard (extand to 20 years)
Display
7.0"LCD color screen display
Grid connection standard
G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1,
VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 /
UNE 206006 / UNE 206007-1, CEI 0-21, C10/11,
NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727,
IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safty/EMC standard
IEC/EN 62109-1/-2, EN 61000-6-2/-3
3000m
Max.operation altitude
MC4 connector
DC connection
Rated output power
3.6kW
3kW
Max. apparent output power
3.6kVA
3kVA
Output AC(Grid side)
Power Factor
Max efficiency
EU efficiency
>
0.99 (0.8 leading - 0.8 lagging)
>96.5%
THDi
<2%
Efficiency
AC grid frequency range
Rated grid output current
15.0 A
45-55 Hz
18.5 A
The grid voltage range
Rated grid frequency
187-265 V
50 Hz
Operation phase
Rated grid voltage
1/N/PE
230 V
Dimensions(W/H/D)
333*505*249mm
-
25
℃~
+60
℃
Weight
Operation temperature range
Ingress protection
IP65
General data
18.3kg
non-isolated
Topology
<
20 dB (A)
Noise emission
Natural convection
Cooling concept
>97.1%
Technical Data
S5-EH1P3K-L
S5-EH1P3.6K-L
Technical Data
S5-EH1P3K-L
S5-EH1P3.6K-L
Rated apparent output power
3.6kVA
3kVA
Inrush current
Max. output fault current
Max. output overcurrent protection
65A 10us
65A 10us
16.0A
20.0A
Protection
DC reverse polarity protection
Short circuit protection
Output over current protection
Surge protection
Integrated AFCI (DC arc-fault circuit protection)
Protection class / Over voltage category
DC Type
Ⅱ
/ AC Type
Ⅱ
Yes
Yes
I / II(PV), II(battery), III(AC)
Yes
Yes
Yes
Ground fault monitoring
Active frequency shifting
Active anti-islanding method