5.6.7.2 ON/OFF
Figure 5.42 ON/OFF
Settings
ON
/
OFF
2015-02-23 19 35
ON
OFF
Y E S
=
< E N T >
N O
=
< E S C >
Enable/Disable the function
.
.
This function should be activated only after the installation
In the case of a low battery
voltage shutdown, the inverter will shut-down. This setting can be enabled, so when the
inverter detects PV or grid it wakes up the battery.
This function conflicts with the battery
reverse polarity protection( If the installer connects cables with wrong polarity the inverter
,
can protect itself from damage).To avoid the possible damage during installation do not
,
active battery wakeup function before finishing the first commissioning.
5.6.6.5 Battery Wakeup
5.6.7 Export power Set
Settings
Figure 5.40 Export
power
Set
Export
power
Set
2015-02-23 19 35
Backflow
Power
ON
/
OFF
FailSafe ON/OFF
Figure 5.41 Backflow Power
Settings
Backflow
Power
2015-02-23 19 35
Y E S
=
< E N T >
N O
=
< E S C >
E S C
U P
D O W N
E N T
Determine the allowed backfeed power. (System export to the grid)
5.6.7.1 Backflow
Power
This function is to set the export power control.
1.Backflow Power. 2. ON/OFF. 3.Failsafe ON/OFF
Setting 1&3 are only valid when Setting 2 is set to "ON"
NOTE:
The export power control function comply with Section 6.3 of
AS/NZS4777.2:2020. Inverter doesn't have the generation control
limit function as in Section 6.2 of AS/NZS4777.2:2020.
.49.
.48.
Hard
Limit
:
S
oft
Backflow
Power
:
OFF
-0000W
Hard
Backflow
Power
:
-0000W