Before Deployment

Before deployment, make sure you do the following:
•  Program your AquaVent logger, using Levelogger Software, with the 

correct project identification, memory mode, sampling regime, time, etc.

•  Set a future start time in the office, or start the AquaVent logger in 

the field using Levelogger PC Software and a laptop, or the Solinst 

Levelogger App & Interface. 

•  Determine borehole depth to ensure AquaVent logger does not touch 

the bottom of the well (avoid submergence in sediment)

•  Record the deployment depth of your AquaVent logger. 

After Deployment 

After deployment, make sure you do the following:
•  Take a manual depth to water measurement after the well has stabilized 

(approximately 10 minutes))

•  Take another manual depth to water measurement just before removing 

the AquaVent logger from the well

AquaVent Field Notes

Note:

  It is useful to synchronize the times of all AquaVent loggers being 

used for the same project.

Note:

  For tips, precautions, and more information on installations in 

different environments and applications, see the latest AquaVent 

User Guide.

Deployment

•  The AquaVent system is designed to be conveniently installed on a 

2" well casing (4" using an adaptor). However, other installations are 

acceptable, if proper precautions and recommendations are followed. 

•  Leave at least 2" (50 mm) of slack in the Vented Cable at surface to 

allow you to lift the AquaVent Wellhead from the well cap base to 

provide access for manual depth to water measurements, without 

disturbing the AquaVent logger from its down hole position.

•  The Wellheads have a rating of IP 64 (dust and splash resistant), so 

should not be submerged at anytime. They can be secured inside an 

enclosure, however, it must be vented to equalize atmospheric pressure. 

•  Do not drop the AquaVent logger into the water, carefully lower it into 

place. Avoid installing in areas where “water hammer” or hydraulic 

jump” (very sudden, large increases in pressure) may occur. 

•  Be careful not to nick or bend the Vented Cable during installation (use a 

maximum 1" (25 mm) bend radius as a precaution).

Note:

  The length of the Vented Cable should not be assumed as the 

deployment depth, as there may be some slack in the cable, 

especially when using the hanger bracket 

•  Use a Solinst Model 101 or 102 Water Level Meter to take a manual 

depth to water measurement that will be used to verify AquaVent 

readings 

•  Determine the minimum and maximum expected water levels, as 

AquaVent loggers must remain submerged for the entire monitoring 

period.

Support Hanger 

Bracket Installation

Содержание AquaVent 3500

Страница 1: ...High Quality Groundwater and Surface Water Monitoring Instrumentation Quick Start Guide 3500 AquaVent Please read this document carefully before using the AquaVent...

Страница 2: ...Wellhead Vented Cable AquaVent Logger 10 Pin SP Connection Alignment socket in the Vented Cable connectors Alignment pin in the Wellhead and logger connectors Coupling Connector Body Line up the alig...

Страница 3: ...gger Settings Window Note Clicking on the embedded in the software will provide you with a short explanation of that feature e g Com Port Slate Mode Time Synchronization etc Starting and Stopping Aqua...

Страница 4: ...view rate is set independently of the logging period of the AquaVent and does not interfere with internal logging taking place To take a reading at any specific time click and that reading will be add...

Страница 5: ...reference datum in the Manual Data Adjustment option in the Software Data Wizard AquaVent loggers detect both water W and barometric pressure B However a vent tube to surface allows barometric effect...

Страница 6: ...g 4 using an adaptor However other installations are acceptable if proper precautions and recommendations are followed Leave at least 2 50 mm of slack in the Vented Cable at surface to allow you to li...

Страница 7: ...ing blue red USB connection has been dropped Flashing yellow The Wellhead is communicating with the PC Software Maintenance As with any monitoring project you should select the proper equipment and de...

Страница 8: ...e bottom of the battery holder 2 Check the Vented Cable connections to the AquaVent logger and Wellhead Ensure they are lined up correctly and there is no dirt or debris in the connection 3 Make sure...

Отзывы: