3-2. Rear Panel Operations
:
WARNING
: REVERSE POLARITY
WILL DAMAGE UNIT
CHASSIS
GROUND
REMOTE
PORT
DC INPUT
NEG(-)
POS(+)
POS(+)
DC INPUT
WARNING
: REVERSE POLARITY
WILL DAMAGE UNIT
CHASSIS
GROUND
NEG(-)
3-2-1. Remote ON / OFF switch for S600R model only.
3-2-1-1. In order for the Remote ON / OFF switch to operate inverter,
ON / OFF switch on the Front Panel must be off.
3-2-1-2. Make sure the remote control contact is off.
3-2-1-3. Using 14 ~ 20 AWG wire, make remote ON / OFF connection
from the Rear Panel Terminal marked “REMOTE PORT” to a
remote control contact. If the remote control contact is in low
impedance ( short ) state, the inverter will be turned ON and if
the remote control contact is in high impedance ( open ) state,
the inverter will be turned OFF.