![Soligent S600 Series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/soligent/s600-series/s600-series_user-manual_1315663018.webp)
4. Troubleshooting guide
:
WARNING!
Do not open or disassemble the S600 Inverter.
Attempting to service the unit yourself may result in a
risk of electrical shock or fire.
Problems and Symptoms Possible Cause
Solutions
No output voltage, ”FAULT" LED lights RED.
a. Fault level light is
blinked fast.
Over input voltage.
( OVP )
Check input voltage.
Reduce input voltage.
b. Fault level light is
blinked slowly.
Low input voltage.
( UVP )
Recharge battery.
Check connections
and cable.
c. Fault level light is
blinked Intermittently.
Thermal shutdown.
( OTP )
Improve ventilation.
Make sure ventilation
openings in inverter
are not obstructed.
Reduce ambient
temperature.
d. Fault level light is ON. Short circuit or Wiring
error.
Overload.
( OLP )
Check AC wiring for
short circuit.
Reduce load.
16
Содержание S600 Series
Страница 1: ...S600 S600R Series Pure Sine Wave Inverter User s Manual ...
Страница 6: ...2 3 Mechanical Drawings P U R E S IN E W A V E IN V E R T E R 4 ...
Страница 20: ...7 1 CE LVD EN60950 Declaration of Conformity 18 ...
Страница 21: ...7 2 FCC Class B Declaration of Conformity 19 ...
Страница 22: ...7 3 e mark e13 020866 Declaration of Conformity 20 ...
Страница 23: ...7 3 e mark e13 020866 Declaration of Conformity 21 ...
Страница 24: ...7 4 UL UL458 NOTICE OF COMPLETION 22 YOUR S D y DISTRIBUTOR SOLIGENT 800 967 6917 www soligent net ...