background image

YOU WILL SEE:

TO   OPERATE   ON   FAN   ONLY:  

DO THIS: 

PRESS

MODE  BUTTON

CHOOSE

FAN ONLY

LIGHT ON 

Note: Use this function only when cooling is not desired

 but room air circulation is needed. You can choose any fan speed you prefer,

EXCEPT AUTO FAN. 

During this function, the display will show the current

 room

 temperature, not the set temperature

.

 

TO USE THE
ENERGY SAVER FEATURE: 

LIGHT ON 

YOU WILL SEE :

DO THIS: 

PRESS

MODE BUTTON

CHOOSE

ENERGY SAVER

TIMER-DELAY YOU WILL SEE 

FIRST DO THIS:

PRESS TIMER

 BUTTON

THEN 

DO THIS: 

PRESS TEMP/TIMER 

BUTTON 

THE TIME CHOSEN:

START/STOP FEATURE: 

LIGHT ON 

Note 1: For 

Auto Off

, the unit must be in the ON position. 

Note 2: For 

Auto On

, the unit must be in the OFF position. 

Note: In this mode, the fan will continue to run for 

a short time after the compressor cycles off.

To adjust timer setting, tap or hold the UP arrow (^) or DOWN arrow (v) to change the delay time by 0.5 hour increments up to 10 hours, 
then by 1 hour increments up to 24 hours. The 

unit

 will count down the time remaining until start (8, 7.5, 7, etc.). After 

set

ting

 

the 

Timer,

 

the unit will enter into Timer mode 

after

 5 seconds, 

and the

 Timer light

 will turn

 on. In Timer mode: 

 

The set temp 

and fan speed

s

 

will be saved

; T

he LED

 display

s the

 set temperature, no

t the current room temperature. 

 

Press

 the

 Timer once,

 and the

 LED

 will

 display remaining time of set time, LED return to set temperature by 5 seconds;

When in Fan Only mode, LED 

will

 display 

the 

room temperature, not display set temperature.Turning the unit "ON" or

"OFF" will cancel the 

Auto ON/OFF

 function. The 

Auto ON/OFF

 feature will work until the unit either starts

or stops. Once this 

happens the timer will need to be reset.

COOL

ING FEATURE 

(on some models)

: YOU WILL SEE

DO THIS: 

:

PRESS

MODE BUTTON

SELECT 

COOL

Note

This feature can be used with any combination of FAN Speeds, Timer, or Sleep Modes. When in the “Cool” Mode, the fan will 

run continuously w

hen cooling

 is needed. The temperature will automatically be maintained anywhere between 61°F (16°C) and 86°F 

(30°C). When the 

set 

room temperature is 

reached

, the fan will cycle off and on to circulate and sample the room air. If the air conditioner 

is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes 
for the compressor to start and cooling to begin.

Air Conditioner Features 

(continued)

11

Содержание SG-TTW-09ESE-26

Страница 1: ...Electronic Through the Wall Air Conditioner Operating Instructions Models SG TTW 09ESE 26 SG TTW 12ESEZ 26 SG TTW 09HC 26 SG TTW 12HC 26...

Страница 2: ...ng installation or repair it is possible to place yourself in a position which is more hazardous than when the unit is in operation Remember it is your responsibility to install the productsafelyandto...

Страница 3: ...oling Capacity BTU Hr 9 200 9 200 8 900 11 800 11 800 11 400 Rated heating Capacity BTU Hr N A 11 000 9 000 N A 11 000 9 000 Cooing Power Input Watt 940 940 910 1 260 1 200 1 160 Heating Power Input W...

Страница 4: ...t claims from dealers for transportation damage Unpacking The Unit 1 Cut the carton banding and open the carton 2 Remove the literature hardware pack upper styrofoam shipping blocks and styrofoam corn...

Страница 5: ...with the wall sleeve for a complete description of the installation proce dure NOTE Wallsleeve PBWS01A isnotshippedwithchassis and must be purchased separately Wall Sleeve Outside Wall Outside Inside...

Страница 6: ...to the sleeve Ensure that the ground wire is not pinched or in the path of the condenser fan 5 Loosen locking plate screw and rotate tab with tab behind wall case flange See Figure C then tighten lock...

Страница 7: ...ted and conditioned When set at OPEN some inside air is exhausted outside Locating Locating Hole Hole Screw Hole Screw Hole OPEN position CLOSE position Mesh end toward back Mesh end toward front Figu...

Страница 8: ...the following warnings and cautions WARNING To avoid the risk of electrical shock personal injury or death do not service this unit without first opening all disconnects and or removing the unit cord...

Страница 9: ...RE TIME TURNS UNIT ON OR OFF TIMER DISPLAYS TEMPERATURE TIME TURNS UNIT ON OR OFF TIMER SLEEP MODE 22 81 7 ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yourself wi...

Страница 10: ...on to turn SLEEP mode on or off SLEEP mode is set to off automatically When SLEEP mode is selected the timer can be adjusted SLEEP mode is not available in Fan or Auto mode Press the FAN button to tur...

Страница 11: ...mer The Auto on time can be set between 5 24 hours The icons T ON and H will flash for 5 seconds Start select ing the time using the and but tons before the icons stop flashing The time will increase...

Страница 12: ...show the LOCK icon in which case the lock icon will flash three times when a key is pressed After the keypad is unlocked the lock icon on the display will disappear When the unit is on the default is...

Страница 13: ...N YOU WILL SEE DO THIS PRESS FAN SPEED BUTTON SELECT AUTO FAN 10 Note Tap or hold either up or down v button until the desired temperature is seen on display This temperature will be automatically mai...

Страница 14: ...er mode after 5 seconds and the Timer light will turn on In Timer mode The set temp and fan speeds will be saved The LED displays the set temperature not the current room temperature Press the Timer o...

Страница 15: ...ned anywhere between 61 F 16 C and 86 F 30 C When the set room temperature is reached the fan will cycle off and on to circulate and sample the room air FAULT CODES SLEEP FEATURE YOU WILL SEE DO THIS...

Страница 16: ...Conditions POPPING OR GURGLING SOUNDS This sound is the refrigerant traveling through the lines This is a normal sound which may be heard for a few seconds after the unit shuts off WATER TRICKLING SOU...

Страница 17: ...Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories ALL WA...

Отзывы: