Installation and Operation Manual (Rev B)
33
the octet. Press the
ESCAPE
button to cancel entry at any point. When the fourth octet is
entered the entry will be saved.
7. Press the
DOWN
button to show the Gateway IP setting.
8. To change the Gateway, press the
ENTER
button.
9. When DHCP is on, the Gateway can either be auto detected or manually specified.
10. To configure the SolrenView gateway to auto detect the gateway from the DHCP server,
select the
“Autodetect”
option in using the HMI.
Autodetect
is the special gateway value of
0.0.0.0.
11. To configure the SolrenView gateway to use a manual gateway, specify each of the four octet
values (0-255), one at a time. Press the
UP
button to increment the octet. Press the
DOWN
button to decrement the octet. Press the
ENTER
button to accept the octet. Press the
ESCAPE
button to cancel entry at any point. When the fourth octet is entered the entry will be saved.
12. Press the DOWN button to access the
Netmask
setting.
Change in the same manner that the Fallback IP was modified.
Содержание PVI 14TL
Страница 58: ...Installation and Operation Manual Rev B 58 ...