background image

 

15 

 

 

 

2.  Feed  the  Ethernet  CAT5  Cable  through  the 

Feedthrough  Body

  (pre-installed  on  the 

enclosure at the factory) and insert the RJ-45 connector to the female connector inside the 
enclosure.  

 

 

3.  Install  the 

Compression  Nut

  and  hand  tighten  until  the  cable  resists  slipping  when  gently 

pushed or pulled. Lightly wrench-tighten, being careful not to overtorque the 

Compression 

Nut

 

 

 

The unit with properly installed feedthrough appears as follows: 

 

 

 

NOTE

  -  Removal  of the  RJ45  plug from the  radio  requires  a tool such as  a  thin 

screwdriver,  or  opened  paperclip.    Care  must  be  taken  not  to  damage  the 
Feedthrough Body or RJ45 plug. 

 

NOTE

 - The total combined length of the Ethernet cables between the radio and 

your network access device (hub/switch/PC) must 

not

 exceed 300 feet.   

Содержание ES700

Страница 1: ...1 SKYWAY ESSENCE SERIES Point to Point PTP Wireless Kit User Guide ES700 September 2016 Rev 1 2a ...

Страница 2: ...for errors contained herein or for incidental or consequential damage in connection with the furnishing performance or use of this document or equipment supplied with it Information to User Any changes or modifications of equipment not expressly approved by the manufacturer could void the user s authority to operate the equipment and the warranty for such equipment Disclaimer In accordance with So...

Страница 3: ... Introduction 13 5 2 Ethernet Cable Feedthrough Assembly 14 5 3 Mounting Bracket and Tools 16 5 4 Unit Mounting 16 5 5 Mounting of Separate Antennas 18 5 6 GPS Antenna Mounting 18 6 WiFi Management 19 7 Ethernet Configuration 21 8 Wireless Configuration 23 9 System Properties 29 10 System Access Configuration 31 11 Antenna Alignment 32 12 Spectrum Analysis 34 13 Monitoring Operation 36 14 Software...

Страница 4: ...i GUI access GP location service unit location GPS synchronization available as a future software upgrade item Channel BW options of 20 40 and 80 MHz Power over Ethernet PoE for simplified cable routing Integrated antenna radio simplifies installation and eliminates lossy RF coax runs Frame aggregation for enhanced data throughput Line speed QoS packet inspection prioritizes latency sensitive real...

Страница 5: ...els ES5723 ES5720 and ES5729 are based on the same wireless radio module The differences are in the antenna gain or use of an external antenna 1 3 Radio Packaging Content The following items are included in each PTP kit package Please contact Solectek Sales if there is any missing item Radio unit 2 POE power supply AC to 48VDC 2 Mast mounting kit 2 Cat5 6 feedthrough gland 2 Coax grommet sealing t...

Страница 6: ...Steps This section summarizes the steps needed to properly configure and install the SkyWay Essence Radio As the background and guidelines for much of the radio installation process are well covered in many in depth publications and training classes only those steps that uniquely relate to the SkyWay product are covered in this User Guide A System Design Requirements analysis Site Survey RF System...

Страница 7: ...nstallation Unit Mounting Spectrum Analysis Antenna alignment E Verification Link status metrics Ping connectivity Performance testing Reliability monitoring F Optimization RF channel tuning Data rate tuning QoS G Management Maintenance Upgrades Access Methods Tools Diagnostics ...

Страница 8: ...s 10 100 1000 Gigabit Ethernet Power Connector 1 WiFi Antenna port N type 2 RF Ports N type female Connectorized PTP unit only The Essence radio interfaces will have additional inte orders hardware options The port configurations for optional features described in separate documents The RJ45 connector is accessed at the bottom of the unit through a multi through If included the RF Ports are access...

Страница 9: ...m View Connectorized unit VIEW SMA CONNECTOR FOR GPS ANTENNA S Connecting the SkyWay Unit to Network Use the diagram below as a guide to cable your SkyWay test system using a PC or Laptop cables An auto MDIX feature eliminates the need for cross SHOWN Use the diagram below as a guide to cable your SkyWay test system using a PC or Laptop MDIX feature eliminates the need for cross over ...

Страница 10: ...Windows OS Enter the TCP IP setup window of Ethernet adapter properties page Set the IP addresses to the following IP Address Setup on your Computer Ethernet IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Open a Web Browser on the Test PC At the URL line type in the following Type of Unit Default IP Address Slave Unit 192 168 1 100 Master Unit 192 168 1 200 LAVE UNITS in your Windows OS Enter th...

Страница 11: ...earance of your GUI will depend on the type and version of your web lease contact Solectek sales and support for detailed The access username is admin and the default password is admin Default Radio Log in Info User Name admin Password admin on the above Windows screen and the Status Overview displayed as shown below Master unit version The details will be reviewed in a later screen may look diffe...

Страница 12: ...o radio units in a PTP link share the same Link ID bandwidth data rate and security settings Access Control List ACL is enabled as a factory default setting It is also important to have identified and prepared the antenna RF coax and Cat5e cable solutions that will be used in the intended application Positioning It is important to remember that the SkyWay radio and antenna system generate and tran...

Страница 13: ... shared volume or an FTP session on a typical Windows Intel machine is not adequate to accurately measure throughput NOTE Units bench tested in an indoor configuration should not be expected to deliver full rated throughput Benchmarking is typically performed after a system is deployed WARNING When it is not in use all optional ports must be plugged in so that there is no water intrusion damage to...

Страница 14: ...ncluded with your SkyWay radio 5 2 Ethernet Cable Feedthrough Assembly Only a single Ethernet cable is needed to connect the SkyWay radio to the indoor PoE Injector Since the cable is exposed to the outdoor elements heat moisture and UV light only outdoor rated shielded Cat5 Ethernet cable should be used To ensure all weather operation the weatherproofing cable feedthrough also known as grommet or...

Страница 15: ...ly pushed or pulled Lightly wrench tighten being careful not to overtorque the Compression Nut The unit with properly installed feedthrough appears as follows NOTE Removal of the RJ45 plug from the radio requires a tool such as a thin screwdriver or opened paperclip Care must be taken not to damage the Feedthrough Body or RJ45 plug NOTE The total combined length of the Ethernet cables between the ...

Страница 16: ... Tools The following figure shows all components of the mounting kit The installation steps will be shown in the next section Tools necessary for tightening bolts and nuts are 10mm wrench for bolts to fasten the L bracket to the radio enclosure 13mm wrench for nuts to tighten U bolt nuts 5 4 Unit Mounting The final installation step involves mounting your SkyWay radio to an outdoor mast ...

Страница 17: ... installation steps bracket on the back of the radio enclosure The hole patterns are symmetric and you can rotate the enclosure by 90 degrees before inst bracket for establishing the radio link with horizontal polarization Using the step bracket and U bolt fasten the L bracket to the mast ate the enclosure assembly in the horizontal direction bracket has a curved groove which can be used to tilt t...

Страница 18: ...onnections is essential This process prevents water from entering the chassis or cables through the connectors In order to provide an adequate seal it is advisable to apply three wrappings 1 electrical tape 2 sealant such as the butyl mastic which is provided with the product 3 electrical tape The first wrapping of tape should be a single layer followed by a generous wrap of butyl mastic Finally a...

Страница 19: ...on to the sky Some obstructions such as a pole and other items may not be The GPS operation will not be interrupted if at least half of the sky is unobstructed 6 WiFi Management ES700 radios have a built in 2 4GHz Wifi module that can be used for accessing the user interface without Ethernet connection First you will need to connect a 2 4GHz omni directional antenna to the WiFi port N of the unit ...

Страница 20: ...ns to external 5GHz antenna for data traffic between radios Once the unit is powered up you can take any wifi client device smartphone tabl The last five numbers represent the last five digits of the unit serial number so as to distinguish among multiple units in the vicinity Once you are connected open a browser and type in the defalt IP address to access the user interface Default IP address 192...

Страница 21: ...ault gateway for the local unit 21 enable disable the WiFi user interface If the interface is enabled it is strongly recommended that encryption is enabled to keep the interface secure Configuration Ethernet Configuration to access the following nfiguration IP address of the local unit Subnet mask of the local unit Default gateway for the local unit the WiFi user interface If the interface is enab...

Страница 22: ... and Save Apply Reset restores the values before you make any modifications Save make the changes effective but does not write such changes to memory Save Apply writes the changes to memory WARNING Make sure that you keep a record of the IP address information of the unit ...

Страница 23: ... remote radio unit Channel Spectrum Width Allows selection of the channel bandwidth BW in MHz of the RF network Allowable options are 20 MHz 40 MHz and 80 MHz If maximizing throughput at shorter distance is of primary importance then larger bandwidth of 40 and 80 MHz may be more appropriate NOTE Both Master and Slave units must be configured with the same Bandwidth setting in order to have the lin...

Страница 24: ...h selection is 40 or 80 MHz this 20MHz channel becomes the in adverse RF conditions The following is a diagram of all available channels Allowable channels of operation for outdoor links depend on the country region Allowed channels of operation in the US are Channel 36 40 44 48 5 15 to 5 25 GHz nnels 149 153 157 161 165 5 735 to 5 85 GHz US FCC version of ES700 is factory configured to operate in...

Страница 25: ...nting for the time of flight for packet transport over the wireless channel Interface Configuration has two different sections General Setup and Wireless Security Mode In a PTP link one unit has to be designated as Master the other Slave The Master unit control the frequency channel and a few other parameters of operation There is no particular requirement for a particular side to be the Master un...

Страница 26: ...e the best TX modulation and MIMO settings based on current RF conditions At power up or reset the ACM function will begin operation at the most robust modulation settings BPSK 1 2 If link conditions warrant higher order settings will be tested and selected for use The ACM function operates continuously i e if RF link conditions change then the modulation and MIMO settings will respond in order to...

Страница 27: ...ardless of link distance or RF conditions You can set the RSSI level you want to maintain the link at typically 50dBm and the Tx power from the other side will automatically adjust its Tx power based on the feedback from the remote unit s benefit is to insure the link quality is consistent overtime and guard against using excessive Tx power especially for short links Excessive Tx power is a big fa...

Страница 28: ...n WPA PSK WPA2 PSK and WPA PSK WPA2 PSK Mixed Mode The default is No Encryption Cipher This specifies the cipher types The choices are Auto CCMP AES TKIP and CCMP AES Key This is the 128 bit key used for AES encryption The key must match between the Master and Slave units for the link to function properly if encryption is enabled The key length has to be at least 8 characters ...

Страница 29: ... current time on the radio unit s time clock The time can be synchronized with the local host computer managing the radio by clicking Sync with local PC word description that the user gives to the radio unit e g e System Name value is completely up to the user and has no effect on System Name can be up to 32 characters long and consist of all wing symbols at sign dash period underscore Name may no...

Страница 30: ...P is enabled above the user can enter NTP server tab will show the following screen System log buffer size kiB This defines the log buffer size The default is 16KB The system log can be uploaded to a remote server The user can specify the IP address of the remote log server here erver Port Specify the port number to be used for connecting to the This specify the types of log items to be uploaded t...

Страница 31: ...etween the regular HTTP mode or sec value is HTTP The port number to be used for web server The default is 80 When you are using HTTPS mode on the radio unit make sure to start in the URL window of your browser Just typing the IP address may not allow access to the radio GUI It is strongly advised that the admin password be recorded and stored in a secure location Password hint fields are case sen...

Страница 32: ...ystem s link capture envelope angle The audible repetition rate will increase as RSSI improves a higher value will cause a faster rate To assist with both coarse and fine tuning the rate is NOT a simple function of RSSI value Rather the rate will continue to increase as long as adjustments deliver an improved RSSI As soon as any degradation alignment overshoot is detected the rate quickly falls re...

Страница 33: ... the audio alignment mode will run before it default value of the interval is 30 minutes button next to the interval will start the audio alignment mode the Run button at this point Click the Stop button to stop the alignment nment process is completed Clicking the Launch button activates the spectrum analyzer mode which will be described in the next section The timer for the audio alignment inter...

Страница 34: ...ned in the general direction of the target radio NOTE If a noise and interference only analysis is desired do not turn on the remote unit during the spectrum analysis as the presence of the remote unit will affect the sweep data NOTE Enabling a spectrum sweep will disable RF traffic until the scanning process is completed NOTE Fluctuations in RSSI values up to 2 dB should be expected This should b...

Страница 35: ...36 to 165 are scanned for RSSI he user can assess which channel would be the cleanest one to be used from the values ease keep in mind that for wider channel operations 40 or 80 MHz you will need several blocks of 20 MHz channels to be relatively clean Refer to the Section 7 for frequency block uses all 20 MHz channels from 36 to 165 are scanned for RSSI he user can assess which channel would be t...

Страница 36: ... Overview to monitor the current status of the system as shown below This screen is for status only Navigate to the Configuration screens if sett This screen periodically updates to the current status at every 2 seconds noteworthy items The elapsed time that the unit has been running since the last reboot or power cycle information is found in the upper right corner of the screen to monitor the cu...

Страница 37: ... the system is displayed here Clicking on the GPS coordinates will lead to a map of the area with the system location pinpointed This is the current Link ID of the local unit Make sure that the Link ID is the same for the local and remote units of a PTP link It is recommended that the user assign a unique Link ID for each PTP link so that there is no unintended RF association with another PTP link...

Страница 38: ...io antenna cable or antenna alignment The user can use this information for diagnostic purposes Noise This is the noise level strength measured by the local receiver It is a measure of the RF noise in the RF path from the remote unit to the local unit Network Section MAC Address This is the Ethernet MAC address of the local unit This is used for identifying the radio in network management Real Tim...

Страница 39: ...dwidth It is a weighted average va calculated per packet basis using the following formula where Tmin is the minimum time that a packet would take at the highest rate without retries and Treal is the time such a packet actually took in real life taking into account CCQ would be lowered if an adverse RF channel condition causes packet losses thus retries and the use of lower transmit rates Backup a...

Страница 40: ...opy will be stored in the tar file format The user can restore the user configuration database to the factory setting Perform reset button During the factory default operation the radio will not be availab for normal operation Because of the changes in the radio configuration the user will need to reconfigure the radio to the proper setting for the PTP link before a link can be established The use...

Страница 41: ...e corruption may occur if power is disrupted during the flash write process System Reboot and Logout to reboot the radio system The following confirmation screen will appear to make sure that the reboot process was not button to reset reboot The reboot process will take approximately is finished the browser refreshed the current page automatically on the menu to log out of the GUI session Similar ...

Страница 42: ...2 and the logout process is now completed Log Log displays all major events that may be noteworthy for the system administrator for both monitoring and troubleshooting purposes Clear Log button will erase all even log entries from the memory Diagnostic Tools access to diagnostic tools navigate to Tools Diagnostics menu to view the following Log displays all major events that may be noteworthy for ...

Страница 43: ...es and host computers You can ping the remote unit from the unit you are accessing via the user interface A default gateway and DNS server are needed to use these tools with a named target Configuration Ethernet Configuration Status ARP to view the ARP status for both Master unit as shown in the screen below There are additional diagnostic tools to arrange automatic rebooting of the unit periodica...

Страница 44: ...t upon detecting that connection to a specified IP address is broken You can specify IP address to Ping Startup Delay sec and Failure Count to Reboot The default In certain situations the user may want to reboot the unit automatically This can ne at a certain time of the day as specified in time or at a given specified time interval e g If enabled Ping Watchdog reboots the radio unit upon detectin...

Страница 45: ...ink ID Back_haul Security Open Access Control List ACL Enabled LAN Others IP Address Slave unit IP Address Master unit 192 168 1 100 192 168 1 200 IP Mask 255 255 255 0 IP Gateway 192 168 1 1 Login Name Password admin admin Ethernet Port Auto Web server mode and port HTTP Port 80 Ping Watchdog Disabled Auto Reboot Disabled Audio Antenna Alignment Disabled Audio Alignment Runtime 30 minutes ...

Страница 46: ... 5 15 5 25 GHz or 5 725 5 850 GHz frequency bands This product has been certified by the U S Federal Communications Commission for use in the United States of America in that band Other markings on the unit label shall indicate regulatory compliance in other international areas Any prospective user of this product outside the United States of America should prior to such use contact the government...

Страница 47: ...persons and must not be co located or operating in conjunction with any other antenna or transmitter For operation in the US under the FCC rules this device has been designed to operate with the antennas listed below and having a maximum gain of 29 dBi Antennas having a gain greater than 29 dBi are prohibited for use with this device The required antenna impedance is 50 ohms This equipment has bee...

Страница 48: ...ed except as allowed under the copyright laws Solectek Corporation makes no warranty of any kind with regard to the material contained in this document including but not limited to the implied warranties or merchantability and fitness for a particular purpose NOTE Changes or modifications not expressly approved by Solectek could void the user s authority to operate the equipment SkyWay and Solecte...

Отзывы: