27
B74/R72
FITNESS
BIKE
GENERAL
MAINTENANCE
1. Wipe down all areas in the sweat path with a damp cloth after each workout.
2. If a squeak, thump, clicking or rough feeling develops the main cause is most likely one of
two reasons:
I. The hardware was not sufficiently tightened during assembly. All bolts that were
installed during assembly need to be tightened as much as possible. It may be
necessary to use a larger wrench than the one provided if you cannot tighten the bolts
sufficiently. Ninety percent of calls to the service department for noise issues can be
traced to loose hardware.
II. The crank arm nut needs to be retightened
III. If squeaks or other noises persist, check that the unit is properly leveled. There are 2
leveling pads on the bottom of the rear stabilizer, use a 14mm wrench (or adjustable
wrench) to adjust the levelers.
MAINTENANCE MENU IN CONSOLE SOFTWARE
The console has built in maintenance/diagnostic software. The software will allow you to
change the console settings from English to Metric and turn off the beeping of the speaker
when a key is pressed for example. To enter the Maintenance Menu (may be called
Engineering mode, depending on version) press and hold down the
Start
,
Stop
and
Enter
keys
Keep holding the keys down for about 5 seconds and the
Message Window
will display
“Engineering mode”. Press the
Enter
button to access the menu below. Press the
Level
/
keys to navigate the menu.
A.
Key Test
B.
Display Test
C.
Functions
I.
ODO Reset
- Resets the odometer reading to zero
II.
Units
- Choose from English(Imperial) or Metric display readings
III.
Display Mode
- Turn off to have the console power down automatically after 30 minutes of inactivity
IV.
Motor Test
- Continually runs the tensioning gear motor
V.
Manual
- Allows stepping of the gear motor
VI.
Pause Mode
- Turn on to allow 5 minutes of pause, turn off to have console pause indefinitely
VII.
Key Tone
- Turn on or off the beep sound when a key is pressed
D.
Security
E.
Factory Settings
- For Factory use only
F.
Exit