![Sole Diesel 29 GS Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/sole-diesel/29-gs/29-gs_operators-manual_1314516038.webp)
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
37
Marine Diesel gensets. Operator’s Manual.
Systems and scheduled
maintenance
Coolant temperature sensor specifications (two pole)
-
Operating voltage: 6-24V
-
Operating current: <85mA, Pmax<0.25W
-
Operating temperature: -40°C to +120°C
-
Measuring range: -40°C to +120°C
-
Absolute max. value: 130°C, max. 1 min.
-
Protection: BODY IP 67
-
Tightening torque: Max. 20Nm
Oil pressure sensor (two pole):
-
Operating voltage: 6-24V
-
Operating current: >20mA, <85mA, Pmax<0.25W
-
Operating temperature: -20°C to +100°C
-
Measuring range: 0
–
10 BAR
-
Absolute max. value: 30 BAR, max. 2 seconds.
-
Protection: BODY IP 67
-
Tightening torque: Max. 20Nm
TEMPERATURE SWITCH:
-
Operating voltage: 12-24V
-
Operating power: 5W
-
Operating temperature: ≤100°C ±4°C (OPEN CIRCUIT), ≥100°C±2°C (CLOSE CIRCUIT)
OIL PRESSURE SWITCH:
-
Operating voltage: 12V
-
Operating power: 5W
-
Operating pressure: 0.98bar (CLOSE CIRCUIT)
TEMPERATURE SWITCH (TWO POLE)
-
Operating voltage: 6-24V
-
Operating power: Max 100W
-
Operating temperature: 96°C ±3°C (CLOSE CIRCUIT)
OIL PRESSURE SWITCH (TWO POLE):
-
Operating voltage: 6-24V
-
Operating current: <0.5A
Operating pressure: 0.4bar±0.15bar (CLOSE CIRCUIT)
Function table
Temperature
(ºC)
Resistance
(ohm)
Tolerance
(ohm)
40
287.4
±32.8
60*
134
±13.5
80
69.1
±6.5
90*
51.2
±4.3
100*
38.5
±3.0
120
22.7
±2.2
*Test point
Function table
Pressure
(BAR)
Resistance
(ohm)
Tolerance
(ohm)
0
10
+3/-5
2
52
±4
4
88
±4
6
124
±5
8
155
±5
10
184
+20/-10