Solaxx Salt3 Скачать руководство пользователя страница 8

1. Maintenance Instructions

It is important to constantly monitor the salt level in your pool for the system to work as efficiently as 
possible. 
The cell should be monitored monthly to make sure calcium buildup is properly addressed. 
Depending on the water quality and hardness, some systems will have to be cleaned more often.

WINTERIZING

Just like the pool plumbing, freezing may damage the system’s components.  If severe or extended 
periods of freezing temperatures are possible, drain all water from the pump, filter, cell and supply 
and return lines before any freezing conditions occur.

6. 

Safely dispose of the acid solution by pouring it into your pool.

7. Rinse the cell with water hose.
8. Put the O-ring back in place and re-install the Cell in the line.
9. If the cell cable connectors were removed make sure they are clean and free of debris and re-

connect them.

Cleaning with Cleaning Cap.

1. Remove the cell from the line by unthreading the barrel unions from the cell ends. There is no 

need to remove the electrical wire connections when using the cleaning cap.

2. Remove the black O-ring on one end of the Cell.
3. Attach the Cell Cleaning Cap to the other end of cell.
4. Pour into the Cell, either undiluted white distilled vinegar, or a solution of diluted muriatic acid (one 

part muriatic acid to 4 parts water). 

Always add acid to water; do not add water to acid!

5. Wait for foaming to stop (5-10 minutes when using muriatic acid; vinegar takes longer).

CAUTION: Do not use metal or other hard objects to clean the cell. Do not insert 
anything into the cell. Both of these actions could scratch the precious metal coating on 
the plates and void the warranty.

CAUTION: Always add acid to water, NOT water to acid.

Diluted muriatic acid solution = 1 part acid to 4 parts water

Note: Follow the instructions of the acid manufacturer.

1

2

3

4

2. Cell Cleaning 

8

MAINTENANCE

Содержание Salt3

Страница 1: ...Installation and Operating Manual LIT 0061 MODEL SALT340A 120 240 VAC 50 60 Hz 2 0 1 1 Amp...

Страница 2: ...it comes with a prewired junction box which is connected to a a power source which will turn the pump and Power Unit on and off together As all individual wiring set ups are unique have the Power Unit...

Страница 3: ...Operating Pressure 50 psi Operating Flow Range 20 100 gpm Water Return to Pool Water From Pool Filter Heater Generator Assembly 1 Ozone Generator 2 Wiring Junction Box 3 Salt Generator Power Supply 4...

Страница 4: ...mperature sensors Polarity DOES NOT matter CLICK TIGHTEN THREADS TIGHTEN THREADS Filter Water from pool Heater Skimmer PLUMBING GENERATOR ASSEMBLY A dedicated return line is best Returns to water feat...

Страница 5: ...N Circuit Breaker Panel 120V Install w o Timer L1 Ground 120V Pump N 1 The Generator Assembly must be mounted vertically on a at surface and a minimum of 5 ft 1 5m horizontal distance or more if local...

Страница 6: ...ON SALT GENERATOR POWER 1 The salt generator power supply will light up Adjust output setting to 3 lights to show output level 2 The ow switch light will remain on 3 Open the ball valve incrementally...

Страница 7: ...generator CONTINUOUSLY FOR 48 HOURS OR LONGER UNTIL THE POOL WATER IS PERFECTLY CLEAR MISCELLANEOUS Remove any fountain attachments on the pool return tting Oxygenated water must be injected directly...

Страница 8: ...free of debris and re connect them Cleaning with Cleaning Cap 1 Remove the cell from the line by unthreading the barrel unions from the cell ends There is no need to remove the electrical wire connect...

Страница 9: ...y Clean lter if necessary Make sure light on bottom of Oxygen Generator is on and bubbles are entering the pool via the returns when system is on Run system for 48 hours on Boost This happens when you...