6
IMPORTANT: ADD SALT TO POOL WATER BEFORE STARTING INSTALLATION
Adding salt to the pool water BEFORE starting the Salt3 system is required. The system
could show error lights on the power supply if there is no salt circulating in the water for
several hours before starting the system. The “Low Salt” light may remain lit up to 24
hours until salt is fully dissolved in the water.
IF USING A VARIABLE SPEED PUMP, MAKE THE ADJUSTMENTS BELOW WITH
THE VSP SETTING MOST COMMONLY USED (USUALLY ABOUT 2500 RPM) FOR
FILTRATION CYCLE.
AFTER EQUIPMENT IS INSTALLED, START THE PUMP WITH THE BALL VALVE
CLOSED 90% TO TRIGGER FLOW SWITCH LIGHT ON SALT GENERATOR
POWER
1. The salt generator power supply
will light up. Adjust output setting to
3 lights to show output level.
2. The flow switch light will remain
on.
3. Open the ball valve incrementally
until the flow switch light goes off.
There is a delay of 5-10 seconds
before the flow switch light goes off
so turn handle a little and wait to see
when light goes off. If not, turn a
little more. When the light goes off,
that is the correct setting.
4. Smaller bubbles are best. After
flow switch light is off, check bubbles
and adjust valve handle a little more
until bubbles are as small as
possible.
5. Check venturi suction. Pull the
ozone tube off the venturi on the
manifold and place finger over the
barbed opening. There should be a
noticeable pull to indicate suction is
present.
EQUIPMENT STARTUP
Flow Switch Light
Output Settings