Ÿ
TURN OFF ALL POWER TO EXISTING EQUIPMENT AT THE BREAKER SWITCH.
Ÿ
BEFORE STARTING INSTALLATION, YOU MUST READ THIS MANUAL IN ITS
ENTIRETY TO ASSURE A SAFE INSTALLATION.
INSTALLATION
A) The Renaissance manifold requires a 12 inch opening in the PVC pipe.
B) Clean the ends of the PVC pipe and glue the Renaissance manifold into opening in the position shown
above.
C) If existing pipe is sized smaller or larger than 2 inch, use adapters to glue manifold (not provided)
D) Water flow is automatically diverted into the UV/Ozone chamber at the proper flow rates. Restriction to
the plumbing is nominal when the manifold is inserted into the plumbing and is comparable to adding a
heater to the pool.
System On
(Flashing - No Flow)
Check Manual
or Our Website
Optimum Water Conditions
pH: 7.2 - 7.6
Total Alkalinity: 80-120 ppm
Stabilizer: 50-80 ppm
Calcium Hardness: 200-400
www.solaxx.com
Pure Water From UV and Ozone
R E N A I S S A N C E
R
Filter
Skimmer
Water
from
pool
Water
return
to pool
Heater
2 Ft.
Renaissance
Manifold
Salt
Cell
10 Ft. Low
Voltage Cable
To Power
Source
Ÿ
1. PLUMBING:
Always mount the manifold on the main return line before the pipe splits into returns for spa, water
features, etc. Install downstream of the heater and before any chlorinators (salt or erosion or feed). If
space allows, install manifold two feet away from the heater to avoid possible safety shutdown of
Renaissance due to hot water conditions in the chamber.
Salt Cell and
Flow Switch are
only shown for
reference if a
salt system is
already installed
4
Содержание Renessance
Страница 11: ...11 ...