Renaissance combines an Ultraviolet Sterilization Chamber with Ozone (O3) disinfection to treat your 
water.  These two powerful processes eliminate 99.99% of all contaminants in water and reduce the use 
of pool chemicals up to 80%. No toxic chemicals are used, no metals or minerals, only pure light and 
pure oxygen.
Using the existing pool pump, a specific amount of water is diverted into the UV/Ozone chamber where it 
is sterilized to the quality of drinking water.   Oxygen infused water is reintroduced into the water flow 
where it continues to oxidize contaminants in the pool itself.  A microscopic residual of chlorine (.5-1.0 
ppm) is recommended for use with Renaissance as a supplemental source of disinfection.   For best 
results, the pool pump should run at least 12 hours daily, (optimally 24 hours daily) for highest savings in 
chemical usage and cost.

1. Ultraviolet Lamp 
produces UV light for 
sterilization and Ozone 
for oxidation

5. Simultaneously, Ozone 
(O3) is captured inside the 
quartz sleeve and 
injected into water as it 
enters the chamber.

3. Using the existing 

pool pump, water flows 

through the chamber 

and is sterilized by UV 

light from the lamp

4. A transparent quartz 

sleeve surrounds the 

lamp insulating it from 

water flowing through 

the chamber

 

2. Chamber Wall

DESCRIPTION

Water Flow To Pool

Water Flow From Pool

3

Содержание Renessance

Страница 1: ...Pure Water From UV and Ozone R E N A I S S A N C E R www solaxx com Installation and Operating Instructions ...

Страница 2: ... components Wear cotton gloves when handling lamps or sleeves Hold bulbs by the ends only Never touch the glass with bare hands Wipe any fingerprints from lamps and sleeves with rubbing alcohol CAUTION This device is for use on private residential swimming pools less then 35 000 gallons Do not use this device for potable drinking water sanitization DANGER ULTRAVIOLET RADIATION Disconnect Power Befo...

Страница 3: ...nts in the pool itself A microscopic residual of chlorine 5 1 0 ppm is recommended for use with Renaissance as a supplemental source of disinfection For best results the pool pump should run at least 12 hours daily optimally 24 hours daily for highest savings in chemical usage and cost 1 Ultraviolet Lamp produces UV light for sterilization and Ozone for oxidation 5 Simultaneously Ozone O3 is captu...

Страница 4: ...ing a heater to the pool System On Flashing No Flow Check Manual or Our Website Optimum Water Conditions pH 7 2 7 6 Total Alkalinity 80 120 ppm Stabilizer 50 80 ppm Calcium Hardness 200 400 www solaxx com Pure Water From UV and Ozone R E N A I S S A N C E R Filter Skimmer Water from pool Water return to pool Heater 2 Ft Renaissance Manifold Salt Cell 10 Ft Low Voltage Cable To Power Source Ÿ 1 PLU...

Страница 5: ...G OILS FOM HANDS ON THE BULB SKIN OILS ATTACH TO THE BULB AND SHORTEN ITS EFFECTIVE LIFE IF BULB ISTOUCHED WIPE CLEAN WITHASOFTCLOTHAND RUBBINGALCOHOL A Unthread and remove the end cap with the wire attached from the end of the UV chamber B Plug the 4 prong plug into the end of the UV bulb C Slide bulb back into chamber D Rethread cap back onto chamber fitting hand tighten only A B C D 5 ...

Страница 6: ...x 240V Install System On Flashing No Flow Check Manual or Our Website Optimum Water Conditions pH 7 2 7 6 Total Alkalinity 80 120 ppm Stabilizer 50 80 ppm Calcium Hardness 200 400 www solaxx com Pure Water From UV and Ozone R E N A I S S A N C E R Ground L1 N Line Pump Power Supply Box 110V Install System On Flashing No Flow Check Manual or Our Website Optimum Water Conditions pH 7 2 7 6 Total Alk...

Страница 7: ...ium Hardness 200 400 OPERATION System On Flashing No Flow Check Manual or Our Website Optimum Water Conditions pH 7 2 7 6 Total Alkalinity 80 120 ppm Stabilizer 50 80 ppm Calcium Hardness 200 400 www solaxx com Pure Water From UV and Ozone R E N A I S S A N C E R When power is supplied to the system the perimeter of the power supply mirrors the LED lights in the center of the faceplate overlay in ...

Страница 8: ...hamber from top of manifold The union nuts should be loosened by hand Note If channel locks must be used to loosen union nuts wrap nut with cloth to prevent cracking or shredding the plastic union nut D Cover manifold openings with caps provided to seal openings Wrap the 4 prong plug around the power supply so the plug is facing down and off the ground Protect the plug by covering the openings wit...

Страница 9: ...WITHASOFTCLOTHAND RUBBINGALCOHOL CLEANING THE QUARTZ SLEEVE The quartz sleeve inside the UV chamber encases the UV bulb and should be cleaned while winterizing the system or annually if system is installed on a pool running 12 months The quartz sleeve is brittle and can be cracked chipped or broken if it is not handled with care Do not remove the sleeve or attempt to scrape or scrub the sleeve as ...

Страница 10: ...components supplied by the factory and only where such components have been installed and maintained in compliance with the respective installation and operation manuals and instructions and applicable ordinances and codes In no event shall the liability exceed the purchase price of the product THE CONSUMER SHALL BE LIABLE AT STANDARD RATES FOR ANY SERVICE VISIT WHERE NO MANUFACTURING DEFECT WAS P...

Страница 11: ...11 ...

Страница 12: ...Pure Water From UV and Ozone R E N A I S S A N C E R www solaxx com ...

Отзывы: