Introduction

Introduction

12

13

3.2 Work Modes

·

In the absence of the external generator, or 

the power is not enough,battery will 
discharge for local loads firstly, and grid will 
supply power when the battery capacity is 
not enough.

     

EPS Status

When the grid is off, system will supply 
emergency power from battery to supply the 
home loads. (Battery is necessary in EPS mode.)

X1-Retro Fit Series inverter provides multiple work modes based on different 
requirements.

Work modes:  

Feed in Priority

Priority:load>grid>battery

This mode applies the area that has high 
feed-in tariff and export control.

Work modes:  

Back up mode

Priority:battery>load>grid

This mode applies the area that has frequent 
power outages. And  this mode ensures the 
battery will has enough energy to supply when 
the grid is off.

Work modes:  

Self-use 

Priority: load>battery>grid

This mode applies the area that has low feed-
in tariff and high energy price.

Work modes:  

Force time use

Priority:battery>load>grid

(when charging)

Priority:load>battery>grid

(when discharg-

ing)
This mode applies the area that has electricity 
price between peak and valley. User can use 
off-peak electricity to charge the battery. 

·

In the case of the external generator, the 

power generated will be used to supply the 
local loads firstly, then to charge the battery. 
The redundant power will export to the 
public grid.

·

The charging and discharging time can be 

set flexibly. 

3.3 Dimension

464.0mm

4

7

6

.0 m

m

180.0 mm

·

In the case of the external generator, the 

power generated  will be used to supply the 
local loads firstly, then export to the public 
grid. The redundant power will charge the 
battery.
·In the absence of the external generator, or 

the power is not enough,battery will discharge 
for local loads firstly, and grid will supply power 
when the battery capacity and power 
generation is not enough.

·

In the case of external power generation 

equipment, the power generated  will be used 
to charge the battery fully firstly, then supply 
the local loads. The redundant power will 
export to the public grid.

·

In the absence of an external power 

generation device, charge the battery with the 
public grid.

·

The inverter will switch to EPS mode only 

when the grid is abnormal.

Содержание X1-Retro Fit

Страница 1: ...this manual belongs to Solax Power Network Technology Zhe jiang Co Ltd Any corporation or individual should not plagiarize partitially or fully copy including software etc and no reproduction or distr...

Страница 2: ...apply to version E I C 4 4 EPS output apply to version E I 4 3 Efficiency Safety and Protection apply to version E I C 4 2 Internal Charger apply to version E I C 4 1 AC output input apply to version...

Страница 3: ...s Danger Danger indicates a hazardous situation which if not avoided will result in death or serious injury Warning Warning indicates a hazardous situation which if not avoided could result in death o...

Страница 4: ...installing or working with this equipment The unit contains capacitors that remain charged to a potentially lethal voltage after the MAINS battery has been disconnected and Hazardous voltage will pre...

Страница 5: ...ould be observed during battery replacement 1 Do not wear watches rings or similar metallic items 2 Use insulated tools 3 Put on rubber shoes and gloves 4 Do not place metallic tools and similar metal...

Страница 6: ...n installing operating and servicing the unit If ignored physical injury or death may follow or damage may occur to the unit Read this instructions before you work on the unit If you are unable to und...

Страница 7: ...rules requires the Live line and Neutral line of that E must with the Live line and Neutral line of grid PS be disconnected applies to most countires SolaX meter Battery DPDT E BAR Main switch RCD RC...

Страница 8: ...d battery grid when discharg ing This mode applies the area that has electricity price between peak and valley User can use off peak electricity to charge the battery In the case of the external gener...

Страница 9: ...installation WARNING 3680 4000 bypass 4600 5000 bypass 4999 5000 bypass X1 Fit 3 7I X1 Fit 3 7C X1 Fit 4 6E X1 Fit 4 6I X1 Fit 4 6C X1 Fit 5 0E X1 Fit 5 0I X1 Fit 5 0C 4 1 AC output input apply to ve...

Страница 10: ...e Storage Operation relative humidity Altitude m Ingress Protection Protective Class Over Voltage Category Cooling Noise emission typical Inverter Topology Communication interface LCD display Installa...

Страница 11: ...t higher than altitude of about 2000m above sea level Not in environment of precipitation or humidity 95 Under good ventilation condition The ambient temperature in the range of 20 to 60 The slope of...

Страница 12: ...enough at least 60mm to support the inverter 1 3 Install the expansion tubes in the holes and tighten them Then install the wall bracket with the expansion screws Installation tools crimping pliers fo...

Страница 13: ...nd insure all conductor strands are captured in the AC terminal 3 5 Compress the AC terminal head by using a crimping pliers and screw down screw cap tightly Step4 Insert AC cable into Grid port throu...

Страница 14: ...ggered either automatically or manually according to user s preference If user wants to use this function manually it will need to be installed an external switch Please refer to specific wiring diagr...

Страница 15: ...range then turn the inverter back on For the nonlinear load please make sure the inrush power should be within the EPS output power range Configuration current less than the maximum dc input current g...

Страница 16: ...munication connection Communication interface bewteen inverter and battery is RS485 or CAN with a RJ45 connector BMS PIN Definition DC plug housing DC socket housing screw connection screw connection...

Страница 17: ...nnector into BMS port inside of inverter and screw it tightly Then insert other side of communication cable into RS485 or Can port on the battery Battery BMS module Pylontech RS485 port Triple Power C...

Страница 18: ...h a Meter fault alert unless the meter function is shut down though CD operation L The smart meter must be authorized by Solax any third party or non authorized meter may not match with the inverter S...

Страница 19: ...nto COM port at the bottom of inverter and screw it tightly Then insert other side of the network cable into PC or other device Step1 Prepare a standard network cable without sheath and find the cable...

Страница 20: ...ection Steps Step3 for the external network cable operation please refer to 485 connection steps Step1 Open the lid cover then it can be seen that a network cable has been inserted in the 485 RJ45 por...

Страница 21: ...Increase power generation subject to constraints from other active DRMs Do not consume power Do not consume at more than 50 of rated power DRM1 DRM2 DRM3 DRM4 Note Only PIN6 DRM0 and PIN1 DRM1 5 are a...

Страница 22: ...lier if needed Pocket Wifi Connection Diagram WiFi Connection Steps Step3 Create a user account online Please check the Pocket WiFi user manual for more details Step1 Plug Pocket Wifi into WiFi port a...

Страница 23: ...test function in accordance with CEI 0 21 During the self test the inverter will consecutively check the protection reaction times and values for overvoltage undervoltage overfrequency and underfrequ...

Страница 24: ...ot modify the program file name or it may cause the inverter not work anymore Update ARM DSP Update DSP Updating 25 Step2 U disk Step3 Warning If the upgrading is broken off during operation please en...

Страница 25: ...em Switch About Date Time Advanced Language Ethernet need password On grid New password Battery Reset Charger EPS system Reset Inv Energy Reset Meter Energy Reset Load Reset Mgr EE Config Guide Reset...

Страница 26: ...main interface User can select interface by moving the cursor with function button and press OK to confirm Menu Status History Setting System Switch About Status U 000 0V I 00 0A P 00 0W Grid 48 49 S...

Страница 27: ...2 EPS Yeild The EPS Yield function contains EPS yield for today and total Today 0 0KWH EPS Yield OutputGridToday 0 8KWH Inverter Yield History Inverter Yield Error Logs Meter Yield EPS Yield Inv Warni...

Страница 28: ...te time English Deutsch Language 3 3 Ethernet There are two modes to obtain IP address static and DHCP User can set the information about ethernet such as IP address subnet mask number and default gat...

Страница 29: ...at needs to be set Charger start time1 Charger end time1 Charger start time2 Charger end time2 Parameter 3 6 Advanced All the advance setting can be set here such as battery grid EPS and so on Advance...

Страница 30: ...50438_NL only Reactive power control Reactive standard curve cos f P For VDE ARN 4105 curve cos f P should refer to curve A default value of setting is as shown in curve A For E 8001 curve cos f P sho...

Страница 31: ...output power allowed If the user do not want feed any power into grid please set it to 0 User value Export Control 4000W Func Select Enable Remote Control connecting 3 6 1 5 Remote Control Remote cont...

Страница 32: ...Click test report to obtian all items test result ALL Test Test report Uvp 27 S1 test Ft 51 50Hz Tt 1000ms Fs 0 00Hz To 998ms F0 0 00Hz pass Ofp2 81 S2 result Vt 264 5V Tt 300ms Vs 0 0V To 200ms V0 0...

Страница 33: ...is sufficient start the Battery Awaken function the inverter will exit the Battery Awaken automatically Battery Awaken Charger NO 3 6 2 2 EPS system For I E Version only X1 Retro fit inverter with I E...

Страница 34: ...er need to work with Energy meter to achieve hybrid functions In hybrid system if there is other power device in the system which is also wanted to be monitored It can install two meters to monitor bo...

Страница 35: ...nd provides you with troubleshooting tips to identify and solve most problems that could occur with the X1 Retro Fit inverters This section will help you narrow down the source of any problems you may...

Страница 36: ...bnormal Check if two MPPTs connect in a parallel mode Please connect the two MPPTs indepedently Or seek help from us if can not go back to normal state Inter Com Fault Internal Communication Fault Or...

Страница 37: ...e check time to time 2 Check that if the indicators of the inverter are in normal state check if the keys of the inverter are in normal state check if the display of the inverter is normal This check...

Страница 38: ...rements Suitable for loads more than 30 kg With handle Can be fully closed Store the inverter in a dry environment where ambient temperature keep always between 20 C 60 C Take care of the inverter dur...

Отзывы: