Setting
Setting
64
65
3-6-3-1) Reset Errorlog
User can reset all inverter errorlog record here.
Reset
>No<
Reset Errorlog
3-6-3-2) Reset Meter Energy
User can reset the meter energy record here.
>Reset Meter1
No
Reset Met Energy
3-6-3-3) Reset MgrEE
Use can reset MgrEE here.
Reset MgrEE
3-6-3-5) Reset Inv energy
Use can reset all inverter errorlog record here.
>Reset
Reset Inv Energy
NO
3-6-3-4) Config guide
This interface will trigger the initial setting guide re-play again.
>Start
Config Guide
>Reset MgrEE
No
Enable
MeterSetting
3-6-4) CT/Meter Setting
X1-Retro fit inverter need to work with Energy meter to achieve hybrid functions.
In hybrid system, if there is other power device in the system which is also
wanted to be monitored, It can install two meters to monitor both solax inverter
and other power device. These two meters need to be set different to address.
Address 001 and address 002 are default and will be written to meters in factory.
So user do not need to change the address except specific situation.
MeterSetting
MeterSetting
1
2
>MeterFunction
>Meter1Addr
>Meter2Addr
•
X1-Retro t inverter can not work with a current sensor(CT) directly.
•
X1-Retro t inverter should keep the meter function” enable”
all the time. ( meterfunction-disable is for other SOLAX hybrid inverter”)
NOTE!
3-6-5) New Password
User can set the new password here.