VERTICAL (THROUGH ROOF) VENTING
INSTALLATION
All part numbers in the following section are shown
in Fig. #6.
1.
Place the flashing (Part A) onto the chase and
seal using silicone.
2.
Put a bead of silicone on the underside of the
vertical standoff (Part B) and place it on top
of the flashing. Align the eight holes and
secure both parts to the chase using eight #8
x 1 1/2" screws provided.
3.
Install the drip shield (Part C) onto the top of
the vertical standoff using a bead of silicone
between the two. Do not screw this part in
place.
4.
Bring the 14-2 electrical wire (not supplied)
up through the holes in both the flashing and
the drip shield leaving at least 12" of excess
wire above the drip shield.
5.
IMPORTANT: Attach an appropriate length(s)
of the vent to the power vent terminal,
sufficient to pass through the chase. Note: do
not connect an adjustable length vent pipe
to the terminal.
Note: do not connect an adjustable length
vent pipe to the terminal.
6.
Seal the connection of the first length of pipe
at the terminal and any other pipe to pipe
joint by both screwing and taping the outside
joint using high temperature foil tape.
7.
Remove the junction box cover. (Part D)
8.
Remove and discard the exhaust shield. (Part
E)
9.
Apply a bead of silicone on the “Part A
Flashing” of the power vent terminal (HRD-
850V)
10.
Slide the vent through the drip shield and at
the same time thread the electrical lead
through the hole in the bottom of the
terminal.
each side of the vertical standoff, the drip shield and
the power vent terminal and then screw them
together using the eight #8 x 1/2" stainless screws
provided.
12.
Join the 14-2 wire lead to the blower wires
using the appropriate connectors and attach
the ground wire. Reinstall the junction box
cover.
13.
Install the vertical rain cap (Part F) over the
power vent blower. ALIGN THE EXHAUST
OUTLET ON THE POWER VENT TERMINAL
WITH THE EXHAUST PORT ON THE VERTICAL
RAIN CAP.
14.
Secure the vertical rain cap to the power vent
blower with the remaining eight #8 x 1/2"
stainless screws.
Note: there are no pilot holes in the base of the
power vent terminal. 1/8" diameter pilot holes
should be drilled using the holes in the vertical
rain cap as a guide.
Do not silicone the vertical rain cap to the power
vent terminal as it needs to be removable for
servicing.
15.
Attach the vent adaptor directly to the
appliance with three screws and seal outer
pipe with aluminum tape provided.
Note:
The inner pipe does not need to be sealed.
16.
Connect the high temperature silicone tube
to the vacuum pressure tap on the adaptor,
secure with the hose clamp provided and
route the tube through any hole back to
Pressure Switch. (Fig. #5)
Note: Ensure that
there are no blockages in this tube, as this
will cause the control to malfunction.
17.
Run the required M&G Duravent GS / Secure
Vent / Selkirk Direct-temp pipe from the
adaptor to the terminal assembly. Assemble
as per the vent pipe manufacturer’s
instructions.
Содержание PV-800HZ
Страница 5: ...4...
Страница 8: ...7 Figure 5...
Страница 10: ...9 11 With the power vent terminal resting on the drip shield align the eight holes in...
Страница 11: ...10 VERTICAL THROUGH ROOF VENTING Final Installation Height 21 Figure 6...
Страница 15: ...14 Disconnect the Red TC spade connector...
Страница 20: ...19...
Страница 21: ...20 V1 2 26 16...