THANK YOU FOR CHOOSING
solasfires.com
We recommend that our
gas hearth products be
installed and serviced by
professionals who are
certified in the U.S. by the
National Fireplace Institute®
(NFI) as NFI Gas Specialists.www.NFIcertified.org
Страница 1: ...ake great pride in every fireplace we make with every product being fully tested throughout the production process to ensure your safety and warmth throughout the years Sincerely The SÓLAS Team SUPPLEMENTAL MANUAL Your Fireplace has been equipped with the SÓLAS next generation control system Please refer to this supplemental manual for operation of the SÓLAS One Touch Remote ONE TOUCH REMOTE ...
Страница 2: ...ame supervision device which will shut off the gas supply if for any reason the pilot flame goes out This device incorporates a fixed probe which senses the heat from the pilot flame If the probe is cool the device will prevent any gas flow unless manually lighting the pilot See full lighting instructions NOTE Periodically conduct a visual check to ensure the pilot and burner flames are as shown t...
Страница 3: ...t automatically lights the pilot Do not try to light the pilot by hand 3 Using the Remote or the optional Wall Touch Pad push the ON OFF button until you hear an audible signal to insure the appliance is off 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas proceed to step 5 5...
Страница 4: ...s and hold the Control Module s RESET button until you hear one short beep and one long beep After the second beep release the reset button 5 Within the subsequent 20 seconds press and hold the button on the Remote for 2 3 seconds will be displayed and flash on the Remote during the pairing sequence The Remote will count up from 1 to 8 and you will hear two short beeps confirming the pairing is co...
Страница 5: ...e breaker Automatic Shut Off in certain conditions Your fireplace s Remote is equipped with an automatic shut off mechanism which is activated in certain conditions See page 38 in the Remote Control Operation section for a description of this feature NOTE Before using the remote control system for the first time the Control Module and the Remote are synchronized at the factory See the section SÓLA...
Страница 6: ...ld Proof Light not used Comfort Blower Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Split Flow Mode not used F or C DO NOT leave the Remote on the hearth mantel or on top of the fireplace Use the Remote wall mount holder provided ONE TOUCH REMOTE MAIN DISPLAY OVERVIEW ...
Страница 7: ...ilot does not stay lit after several tries call your local service technician or gas supplier TO TURN OFF FIRE Press to turn OFF When the pilot is off it will take 2 minutes before it can be lit again NOTE There is a 2 minute delay after switching off before the next ignition is possible CAUTION Always check the fire and pilot visually to ensure they are off FLAME HEIGHT ADJUSTMENT To increase fla...
Страница 8: ...hold simultaneously 2 disappears Child Proof is now inactive and the Remote has full function COUNTDOWN TIMER You can set your fireplace to automatically turn off at the end of a timer To set a Countdown Timer 1 Press and hold until is displayed Hour flashes 2 Press or to select Hour 3 To confirm press Minutes flash 4 Press or to select Minutes 5 To confirm press or wait To turn off a Countdown Ti...
Страница 9: ...erature for Thermostatic Mode is the temperature for the ON time in Program Mode Changing the Thermostatic Mode set temperature also changes the ON time temperature in Program Mode Default Settings ON TIME Thermostatic TEMPERATURE 70 F 21 C OFF TIME TEMPERATURE pilot flame only Temperature Setting 1 Press and hold until flashes ON and set temperature set in Thermostatic Mode is displayed 2 To cont...
Страница 10: ...te This could cause a short circuit NOTE The batteries in your SÓLAS One Touch remote control and control module are to be replaced annually Only use brand name alkaline batteries such as Duracell or Energizer Remote The battery icon will show when the battery needs to be replaced Replace with two 1 5 V AAA alkaline batteries Control Module Frequent beeps for 3 seconds when the motor turns indicat...
Страница 11: ...3 failed ignition sequences F06 shown No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring F06 F06 4 seconds 3 failed ignition sequences in 5 minutes Fire is not responding no pilot flame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot orifice if valve has been converted from LPG to NG or vice versa F07 Lo...
Страница 12: ...OSING solasfires com We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists www NFIcertified org ...