background image

12/06/99 

IF THE RED AND GREEN LIGHTS ARE ON, WITH ALL OTHER LIGHTS OFF AND THE PUMP DOES 
NOT RUN: (IN GOOD SUNLIGHT)  
 
 
4. Check for proper controller output voltage. Connect a DC volt meter across 
terminals 2 LD- and 3 LD+ on the large terminal block. If no voltage is 
indicated, check the fuse. If the fuse is good and there is no voltage on the 
output, the controller has an internal problem and must be sent back to the 
factory for repairs. 
 
 
If the voltage on the output terminals is about the same as the open circuit 
voltage then check for an open circuit between the controller and the pump 
motor. Check the wiring and the wire splice. If there is open circuit voltage on 
the pump side of the splice and the motor does not run then there is an open 
circuit in the motor. This indicates the motor has an internal problem and must 
be sent back to the factory for repairs.  
 
If the voltage on the output terminals is very low, then disconnect the pump 
wires and check again. If the voltage goes to open circuit, then a high current 
load is indicated. Usually a high load will trigger the over-current circuit and 
will turn the controller off and at the same time turn the orange light on. To 
reset this circuit, turn the on/off switch off and back on again  
 
5.   Testing an SCS Brushless DC Motor.  
To check an SCS Brushless DC motor, take an ohm meter and set to a meg-ohm 
scale. Connect the negative lead on the meter to the positive lead on the motor 
and the positive lead on the meter to the negative lead on the motor. The 
reading should be over 10 meg- ohms if measuring through the drop wire with the 
motor in the well. If measuring a dry motor only at the surface it should read 
over 100 meg-ohms. This test is for the polarity protection diode.  
 
To check the FETS connect the positive meter lead to the positive motor lead and 
the negative meter lead to the negative meter lead. If the FETS are shorted to 
ground the meter read around 2000 to 5000 ohms and steady. If they are not 
shorted it read about 1 to 5 meg-ohms at first and as the internal capacitor 
charges it will drift higher.  

Содержание PCB-120

Страница 1: ...PCB 120 DC SUBMERISIBLE PUMP CONTROLLER USER S MANUAL...

Страница 2: ...rrent boosting in low sunlight conditions PCB 120 SPECIFICATIONS 1 HP Input Voltage 100 180V open circuit Eight Panels in Series Max Maximum Output Current 10 AMPS Maximum Surge Current 18 AMPS Maximu...

Страница 3: ...If you change the voltage setting using the adjusting pot it will change the set points on all 4 selector switches It is highly recommended you do not adjust this pot SELECTOR SWITCH SETTINGS Switch...

Страница 4: ...y running in low water conditions Please be advised that this circuit does not work in all situations With switch 1 in the OFF position it becomes a high water cut off circuit tank fill This keeps a s...

Страница 5: ...the panels away from the sun until the pump flow rate is reduced by approximately 50 If this is not possible then shade the panels slightly until you obtain the same results This puts the controller...

Страница 6: ...to test for proper power is to check input voltage and current and output voltage and current This will indicate where to start looking for the problem If a volt and amp meter is not available then a...

Страница 7: ...pump wires and check again If the voltage goes to open circuit then a high current load is indicated Usually a high load will trigger the over current circuit and will turn the controller off and at...

Страница 8: ...12 06 99 8...

Страница 9: ...12 06 99 9...

Страница 10: ...atsoever of the product voids all warranty Warranty limitations There are no express warranties except as listed above SOLARJACK shall have no responsibility for damage to property persons animals or...

Отзывы: