4
Notice:
1.To get enough air for ventilation of the unit, the installation position should be with good ventilation.
2.The installation position can hold the outdoor unit without noise and shake.
3.No sunlight to the unit. Set an awning if necessary.
4.The water from rain and defrosting can be discharged in the installation position.
5.The unit will not be covered by snow in the installation position.
6.The discharged air will not face strong air in the installation position.
7.Assure the noise caused by the unit ventilation and operation will not affect the neighbor.
8.The installation position will not be affected by garbage, oil and mist.
9.The outdoor unit will be damaged under the condition with oil(engine oil), salt(sea area) and
sulfide air(near thermal spring and refining factory).
Adapter connector
Needle valve
valve plug
valve plug nut
Needle valve
nut
Adapter connector nut
Indoor unit and outdoor unit
copper connecting pipe
Stop Valves
2.
The refrigerant piping connection for split type unit
2.1
Each component's names and function of refrigerant stop valve
Adapter connector
Needle valve
Valve plug
The connecting pipe joint of indoor unit and
outdoor unit .
To discharge the air in the connecting pipe
and outdoor unit by refrigerant pressure or
connect a vacuum pump.
Turn on or turn off the stop valves.
II. Installation
1. unit installation position
The pretty high condensation temperature (cooling) and pretty low evaporation temperature
(heating) will affect the operation of outdoor unit. To achieve maximum efficiency, please select
the installation position under below regulations:
To avoid ventilation short, the outdoor unit discharged air should not return when installation.
Please keep enough space around the outdoor unit for repair. Right and wrong means as below:
Wrong
Right
Содержание SunPump MACHRW010W
Страница 1: ...DC INVERTER AIR TO WATER HEAT PUMP INSTALLATION INSTRUCTION MANUAL Sun Sun tm Pump Pump ...
Страница 2: ......
Страница 30: ......
Страница 31: ......