SAFETY, INSTALLATION, AND OPERATIONS MANUAL
© The Solaria Corporation
Contents subject to change without notice.
U.S. and International patents issued and pending
Document PSC-0004 Rev 02, November 2010
10 of 12
7.
FRAMELESS ELECTRICAL SPECIFICATIONS*
Solaria 230 Solaria 220 Solaria 210
Peak Power, Pmax (Watts)
230
220
210
Open Circuit Voltage, Voc (V)
43.02
42.30
41.59
Short Circuit Current, Isc (A)
7.24
7.19
7.13
Voltage at Pmax (V)
34.20
34.03
33.81
Current at Pmax (A)
6.71
6.46
6.21
Cells
Monocrystalline
Bypass Diodes
5 – 1 per String – 5 Strings
Ratings
15 Amps each
Max Vrrm
45 Volts
Type
ZJRH PVS105
Isc
3.10
mA/
º
C
Imp
4.10
mA/
º
C
Voc
-166.5
mV/
º
C
Vmp
-180.0
mV/
º
C
Pmax
-1.140
W/
º
C
•
Serial Number Label
• Traceability for date and place
of manufacture
FRAMELESS
ELECTRICAL
PARAMETER
ELECTRICAL
TEMPERATURE
COEFFICIENTS
z
Specified power rating is + 5/- 2% of indicated value of Pmax under STC
z
All other electrical specifications are + or - 10% of indicated values under
STC
z
STC : Irradiance 1000 W/m
2
, AM 1.5 spectrum, Cell Temperature 25º C
z
Module is rated for Application Class A
4-color
2-color
1-color
4-color
1-color