background image

SAFETY, INSTALLATION, AND OPERATIONS MANUAL 

© The Solaria Corporation 

Contents subject to change without notice.

U.S. and International patents issued and pending  

Document PSC-0004 Rev 02, November 2010

8 of 12

1” long  5/16”- 18 hex bolt

#93190A583

5/16”- 18 hex nut

#94804A030

5/16” flat washer

#91525A229

5/16” spring lock washer

#92147A030

 4.3.

  MODULE DIRECTION AND TILT ANGLE

z

Modules produce maximum energy when they are 
pointed directly to the Sun. Modules get maximum 
sunlight throughout the year when they face South 
in the Northern Hemisphere and when they face 
North in the Southern Hemisphere.

z

When mounted on a single axis tracker, modules 
may be tilted or kept horizontal. Tilting will 
produced more annual energy.

 4.4. 

MODULE ORIENTATION

z

Fixed Tilt Rack:

 Solaria modules are not designed 

for fixed tilt rack mounting. Fixed tilt rack mounting 
will result in poor power production.

z

Single Axis Tracker:

 Modules should be tracker 

open rack mounted such that the cell lenses are in the North-South direction. This orientation is 
called Landscape Mount. It positions the cell lenses parallel to the axis of rotation. 

z

Dual Axis Tracker:

 Modules should be tracker open rack mounted such that the cell lenses are 

parallel to the azimuth axis of rotation. This orientation is called Portrait Mount. IMPORTANT: In this 
orientation, frameless module safety hooks may be required to prevent modules from slipping due to 
thermal expansion.

  5.

  MAINTENANCE

Solaria modules are virtually maintenance free. Following simple maintenance steps will ensure reliable 
production of DC electric power for the expected life of the product.

z

Inspect electrical and mechanical connections for safety and corrosion at least once  
every year.

z

Under most weather conditions, normal rainfall is sufficient to keep the module glass surface clean. 
However, modules that are mounted at small tilt angles will not self-clean as easily as modules that 
are mounted at large tilt angles. If dirt build-up becomes excessive, clean glass surface with water 
and soft cloth. DO NOT use harsh cleaning materials.

RECOMMENDED 
MCMASTER CARR 
STAINLESS STEEL 
HARDWARE PART 
NUMBERS

4-color

2-color

1-color

4-color

1-color

Содержание 210W

Страница 1: ...color color color color color Solaria Frameless 230W 220W 210W Module Series Mono crystalline Solar Panels 156x156mm Cells SAFETY INSTALLATION AND OPERATIONS MANUAL North America and Europe...

Страница 2: ...igher than 240W where general contact access is anticipated modules qualified for safety through EN IEC 61730 1 and 2 within this application class are considered to meet the requirements for Safety C...

Страница 3: ...HE FOLLOWING PRECAUTIONS TO AVOID FIRE HAZARDS Refer to your local authority for guidelines and requirements for building and structural fire safety The roof construction and installation may affect t...

Страница 4: ...the module label Connection cables and wiring must be supported with cable ties and clips to the module support structures DO NOT use module junction boxes to support cables and wiring Under normal c...

Страница 5: ...module in a string of modules causes reverse voltage across the shaded cells This results in current being forced through the shaded cells causing module heating and severe power loss The bypass diode...

Страница 6: ...he application z z Clearance of 7mm or more between frameless modules is required to allow for thermal expansion of the tracker rack mounting hardware z z The back surface of the module must always be...

Страница 7: ...mm from the edge See following figure for allowed clip locations Note the following z z For each module use four sets of stainless steel hardware each set 5 16 18 hex head bolt at 8mm diameter hex nut...

Страница 8: ...nses are in the North South direction This orientation is called Landscape Mount It positions the cell lenses parallel to the axis of rotation z z Dual Axis Tracker Modules should be tracker open rack...

Страница 9: ...or expense arising out of or in any connection with such installation operation use or maintenance of the modules z z The Solaria Corporation assumes no responsibility for any infringement of patents...

Страница 10: ...3 81 Current at Pmax A 6 71 6 46 6 21 Cells Monocrystalline Bypass Diodes 5 1 per String 5 Strings Ratings 15 Amps each Max Vrrm 45 Volts Type ZJRH PVS105 Isc 3 10 mA C Imp 4 10 mA C Voc 166 5 mV C Vm...

Страница 11: ...Solaria Corporation Contents subject to change without notice U S and International patents issued and pending Document PSC 0004 Rev 02 November 2010 11 of 12 8 FRAMELESS MECHANICAL SPECIFICATIONS z z...

Страница 12: ...t CA 94555 United States of America T 1 510 270 2500 F 1 510 793 8388 Solaria Germany Oranienburger Strasse 23 D 10178 Berlin Germany T 40 30 233 297 97 F 49 30 275 748 56 Solaria India 202 SSH Pride...

Отзывы: