5 Use and operation
5 Use and operation
Touch display for operation
When the display is supplied with power, the
eco
mana-
ger-
touch
control starts. The control is started up to
show the main screen.
i
Operate the touch display with your fingers,
do not use any hard or pointed objects.
If no inputs are made for 5 minutes (factory setting),
the display will switch to standby mode.
Tapping the display again restarts the display with the
main screen.
Buffer battery in operating element
A replaceable buffer batter (CR2032) ensures that
data (time, settings) are retained in the operating ele-
ment when the power supply is switched off.
5.1 Main screen of the control
Abb. 2-8: Main screen
1 Software version for control
2 Outside temperature
3 Power (speed of the compressor)
4 Operating mode
5 Flow temperature of the heat pump
6 Status line
Tapping the main screen changes to the
Selection
menu
5.2 Operating mode
STOP
Heat pump and electric heating element are switched
off. No heating requirements of the connected devi-
ces are fulfilled.
i
Frost protection function is guaranteed. If the
outside temperature falls below +2°C (factory
setting), the primary circuit circulation pump
and, if necessary, the compressor (or electric
heating element) are switched on.
START
After pressing the START button, the heat pump is
ready for operation, and is able to fulfil heating
requests from the connected devices. The heat pump
goes into standby status as soon as a heating
request is fulfilled, or the time release
Blocking times for electric heating element/heat
pump
is no longer available.
electric heating element only
The heat pump is switched off. Heating requests are
met by the electric heating element. Usage: For
exceptional situations, e.g. in case of a compressor
operating fault.
Automatic defrost
At temperatures below 5°C, the water contained in
the outside air settles on the evaporator of the heat
pump in the form of frost and ice.
The defrost is automatically triggered by the control at
regular intervals by heat is supplied to the evaporator
by circulatory reversal.
5.3 Selection menu
Abb. 2-9: Selection menu
1 Customer menu
2 Heating circuit
3 Domestic hot water heating
4 Weatherman function (optional)
5 Information
Operation manual
vampair
13