K 15
GWP (according to EN 378), kg CO2 equivalent per kg
[kg/kg]
4.78
4.78
6.7
6.7
CO2 equivalent
[t]
9.98
9.98
13.99
13.99
Condenser material
1.4401/Cu
Operating limits
Operating limit outside air min.
[°C]
-22
Operating limit outside air max.
[°C]
35°C
Operating limit heat-side air min.
[°C]
26°C
Operating limit heat-side air max.
[°C]
65°C
Operating limit outside air at W60
[°C]
-22°C
Operating limit outside air at W65
[°C]
-5
Water hardness
[°dH]
4 – 8.5
pH value
7.5 – 9
Conductivity
[μS/cm]
10 – 500
Free chlorine
[mg/l]
< 0.5
Electrical data
Protection type (IP)
IP X4
- 1-phase version (K 08.1, K 10.1, K 12.1, K 15.1)
Number of compressors
1
-
Compressor connection
~230 V, 50 Hz,
5,5 kW
-
Control connection
[A]
~230 V 50 Hz
-
Compressor fuse
[A]
25
-
Control fuse
[A]
10
-
Starting current
[A]
15
-
- 3-phase version (K 08.3, K 10.3, K 12.3, K 15.3)
Number of compressors
1
Compressor connection
~400 V, 50 Hz;
5,5 kW
~400 V, 50 Hz;
8 kW
Control connection
~230 V, 50 Hz
Auxiliary heating power consumption max.
[kW]
3 / 6 / 9
Auxiliary heating connection
~400 V, 50 Hz
Compressor fuse
[A]
13
16
Control fuse
[A]
10
10
Auxiliary heating fuse
[A]
13
13
Starting current
[A]
6.5
8
Dimensions
Height
[mm]
1090
1325
Width
[mm]
1580
1580
Depth
[mm]
870
920
Weight
Weight (including packaging)
[kg]
348
373
401
426
Connections
Connection for heating flow/return
["]
G 5/4" OT
Flow rates
Air flow rate
[m³/h]
1300
2900
2000
4400
Min. heating volume flow rate
[l/h]
520
520
800
800
Min. heating volume flow rate for defrosting and com-
missioning
[3]
[l/h]
1560
1560
2500
2500
Heating volume flow rate, at OT7/W35 and 5 K
[l/h]
1080
1080
2080