For your safety 

Installation manual 

pellet

top

 

Classification of warnings 

The warnings used in this manual are shown with symbols and signal words. The signal word indicates the level 
and nature of the danger and how to avert it. 

 

 

Dangerous situation for humans! 

Indicates a hazard with a high degree of risk, which 

– if not avoided – will cause 

death or a serious injury.

 

Dangerous situation for humans! 

Indicates a hazard with a low degree of risk, which 

– if not avoided – could cause 

minor or moderate injury.

 

 

Dangerous situation for humans! 

Indicates a hazard with a medium degree of risk, which 

– if not avoided – could 

cause death or a serious injury.

 

Attention! 

Risk of property damage. Indicates operations or circumstances which may result in damage to the product. 

Note: Indicates information for correct handling of the product.

 

Symbols and labelling 

 

Bullet point 

 

Precondition for an action 

 

Instruction 

 

Result of an action 

Numbering of figures 

The numbering can be found below the figures, for example: Fig. 6-3 
6-3 stands for the unique identification of the figure and is used in the text if the figure is referenced. The num-
ber 6 stands for the main section of the manual where the figure can be found, the number 3 for the serial num-
ber of the figure within the main section of the manual. 

Limitation of liability 

SOLARFOCUS GmbH is not liable for personal injury and property damage due to: 
Failure to observe the instructions in this manual. 
Use of the product for any purpose other than for its intended use. 
Deployment of non-qualified personnel. 
Use of non-approved spare parts. 
Technical modifications to the product by the user. 

Copyright 

This manual is protected by copyright. Reprinting, translation and reproduction of this manual 

– in its entirety or 

in part 

– is only permissible with the prior written approval of the manufacturer. 

Warranty 

See terms and conditions of business and delivery of SOLARFOCUS GmbH. 

 

 Contact your heating engineer or the SOLARFOCUS service department for further information. 

For your safety 

 Make sure that you read this manual before commissioning the product. Compliance with the instructions in 

this manual, particularly the safety instructions, is vital for safe operation. 

Safety information 

  Do not use or store combustible materials in the vicinity of the boiler. 
  When opening the boiler door, ensure that no flue gas or flying sparks escape. Never leave the boiler door 

open and unattended. 

  The boiler must be switched off before filling the storage room! 
  Never open the combustion chamber door during operation. 
  Only touch the designated operating elements (handles) while the boiler is in operation. Other components 

(combustion chamber door, flue gas pipe, …) can become very hot – danger of burns! 

  In the event of damage to the insulation, switch off the power supply immediately and have the insulation 

repaired. 

  Protect live parts against moisture. 
  Do not allow unauthorised persons, children or animals to enter the boiler room. Persons who are unfamiliar 

with the boiler or have received no instruction in its use must not be allowed to operate it. 

  Use only fuel which meets the prescribed quality standards. 
  Do not use auxiliary materials to ignite the prescribed fuel. 
  Have maintenance work performed regularly (contact the SOLARFOCUS GmbH Service Department or an 

 DAN-

GER

 

 CAUTION

 

WARNING

 

Содержание pellet top touch 35

Страница 1: ...Read carefully before operating Pellet boiler pellettop touch Installation manual for qualified personnel DR 6015 EN v18 202002...

Страница 2: ...rload protection 14 6 4 Return flow boosting RFB 15 7 Electrical connection 16 7 1 Connections to the boiler power element 16 7 2 Power supply for the heating system 17 7 3 EMERGENCY OFF switch 17 7 4...

Страница 3: ...pproved spare parts Technical modifications to the product by the user Copyright This manual is protected by copyright Reprinting translation and reproduction of this manual in its entirety or in part...

Страница 4: ...egional guidelines directives and laws pertaining to the operation of wood and pellet fired combustion systems The modification or disabling of safety equipment is strictly prohibited The fire buildin...

Страница 5: ...pe diameter cm 15 15 20 20 Height flue gas pipe centre 1 D cm 46 46 59 59 Flue gas mass flow full load g s 30 37 40 55 Flue gas mass flow partial load g s 10 13 5 14 20 Max flue gas temperature full l...

Страница 6: ...small parts 2 1 Ash scraper 3 1 Ash pan 4 1 Operation manual pellettop 5 1 Transparent bag with 2 x ash pan handles 4 x hinge bolt hose clamps 1 x stainless steel combustion grate 4 x adjustable feet...

Страница 7: ...glow pencil 12 Stainless steel combustion grate 13 Ash container 14 Combustion chamber pellettop 49 70 1 Motors for heat exchanger clean ing 2 Lambda sensor 3 Cladding door 4 Operating unit 5 Suction...

Страница 8: ...rted to the back of the boiler pellettop 49 70 in addition from the boiler top 2 x ring screws M20 1 mountable not included in the scope of delivery Fig 4 1 Fig 4 2 4 2 Removing the shipping timber pe...

Страница 9: ...ontainer will be mounted on The cables for the ash extraction auger motors and the cover switch for the ash container are laid on both sides of the boiler The following procedure describes the install...

Страница 10: ...2 Fig 5 5_Fitting the augers Install the ash extraction augers Insert the augers 1 Turn the augers to ensure that the bayonet lock socket at the end of the auger latches into the catch on the motor F...

Страница 11: ...d as follows Unscrew the switch from the boiler Release screws at switch head 3 and turn head 180 degrees Release screws at roller lever 4 and turn head 90 degrees Replace the switch on the boiler pos...

Страница 12: ...ole for emission measurement Make the hole for the emission measurement according to the following images recommendation according to standard If these specifications cannot be implemented then make t...

Страница 13: ...ntent of the system l kW Boiler output kW Example 1166 litres 46 64 l kW 25 kW Overall output of heat supply German hard ness Specific water content of the system 20 l kW 50 kW 16 8 dH 50 kW to 200 kW...

Страница 14: ...overload protection 4 Drain 5 Sensor for thermal overload protection Dimension of connections Technical specifications 5 6 3 Thermal overload protection Fit the thermal overload protection valve befor...

Страница 15: ...oster is a guarantee condition of SOLARFOCUS During installation make sure that there is a clearance 20cm between the boiler and the return booster module to allow for subsequent replacement of pump c...

Страница 16: ...Room sensor HC1 optional X42 Outside temperature sensor Boiler X4 Automatic ignition X16 Automatic ash extraction X19 ID fan X20 Overtemperature reset OTR X23 Feed motor X24 Heat exchanger cleaning X...

Страница 17: ...ent covers Fig 7 2 Cable duct 1 for sensor lines on the left side of the boiler Cable duct 2 for power lines on the right side of the boiler Power element cover 3 Lower cover 4 7 5 System type Suction...

Страница 18: ...use the following functions mySOLARFOCUS app Weatherman function IP VNC Remote access to the boiler control Sending e mails 7 8 Types of sensors overview Measuring sleeve Cable Sensor type Art No Use...

Страница 19: ...ating Size Function F1 T 3 15 A 5x20 mm Fuse 230V AC Pre fuse main transformer F2 T 125mA 5x20 mm Fuse 230V AC Pre fuse standby transformer F3 T 10 A 5x20 mm Fuse 230V AC Relay outputs F5 F 8A 5x20 mm...

Страница 20: ...ture resistance of the hose 60 C Route hose as straight as possible To avoid sagging use the SOLARFOCUS item support shell made of zinc plated sheet steel The hose must be attached to the floor at sev...

Страница 21: ...lows the door to be opened when the storage area is full We recommend that you provide a means of checking the filling level of the store by eye e g by cutting small windows in the wooden boards Posit...

Страница 22: ...equirements with regard to the weight load imposed by the pellets bulk weight 650 kg m The perimeter walls and the storey ceiling must meet the requirements of the respective fire resistance classes I...

Страница 23: ...ny specimen firing ordinance For heating appliances with a nominal output of up to 35 kW a combustion air opening of at least 150 cm or 2 x 75 cm routed directly into the open air must be provided Alt...

Страница 24: ...pellettop 9 5 Storeroom and conveying system Overview Suction system with suction heads Suction system with suction auger Suction system with suction heads and sloping floor Pellet box with suction sy...

Страница 25: ...Annex Installation manual pellettop 25 Boiler cascade solution with different storage conveying system...

Страница 26: ...Annex 26 Installation manual pellettop 9 6 Commissioning log...

Страница 27: ...Annex Installation manual pellettop 27...

Страница 28: ...Annex 28 Installation manual pellettop 9 7 Customer service order form...

Страница 29: ...Annex Installation manual pellettop 29...

Страница 30: ...Annex 30 Installation manual pellettop...

Страница 31: ...Annex Installation manual pellettop 31...

Страница 32: ...products that take the strain off the envi ronment and your wallet Everything from a single source Biomass heating Solar systems Heat pumps Fresh water equipment Tested leading edge technology EN ISO...

Отзывы: