18 Messages
18 Messages
Messages that arise are shown in the
eco
manager-
touch
control display, each message is saved in the
message log
.
Abb. 2-62: Information window with message
Handling of messages
–
Button
1
: Close window, change to main screen.
The message remains active, i.e. the burner may
not start depending on the type of message.
–
Button
2
: Switch to the
message log
–
Button
3
: Acknowledge the message.
For some messages, an acknowledgement is
only possible if the cause of the fault has been rec-
tified; the burner may then restart after a heating
request is received.
A message is visible at the top edge of the main
screen until it is acknowledged
1
. Press to ack-
nowledge the message (information window opens)
Abb. 2-63
Alarm symbol
This symbol indicates an alarm message: The
boiler is no longer ready for operation if such a mes-
sage occurs.
Note symbol
This symbol indicates a notification message:
The boiler is still ready for operation.
Possible messages
No. Message
1 Internal memory is invalid
2 Feeder sensor short circuit
3 Filling level sensor may be dusty
5 Flue gas temperature too low
6 Flue gas sensor disruption
7 Flue gas sensor wrong measured value
8 Feeder sensor disruption
9 Flue gas sensor short circuit
10 Factory settings loaded
11 Error rotational speed feedback
12 Rotational speed feedback test
13 Rotational speed feedback Not OK
14 Maximum suction run time reached
15 Error feed sensor measured value
16 Error lambda sensor measurement
17 Error boiler temperature sensor
19 Extraction auger is blocked
20 First ignition attempt was unsuccessful
23 Communication with module interrupted
24 Safety chain has triggered
25 A power failure has occurred
26 Mains fuse F3 defective
27 Triac fuse F6 defective
30 Feed blockage
31 Heat exchanger is blocked
32 Heat exchanger is blocked
33 No feed motor current flow
35 CAN bus interruption
36 Fuse at fresh water module defective
37 A fuse in the electronic module (solar module) is
defective
38 Commissioning settings have been loaded
40 Pellet ignition fault/pellet shortage?
41 FUSE F1 or F8 defective
42 Shortage of pellets in storage area
43 Fault in diverter for suction heads
44 Communication error cascade
46 The ash container is full and must be emptied
47 Heating boiler maintenance recommended!
51 Battery in operating element (display) is dead
52 Limiting thermostat is open
67 Room air flap does not open
68 Room air flap does not close
69 Error communicating with the room air module
71 No current flow heat exchanger
72 Note: No current flow heat exchanger
42
Operation manual
maximus L