![SOLARFOCUS maximus L 150 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/solarfocus/maximus-l-150/maximus-l-150_operation-manual_1313805011.webp)
3 Warranty, guarantee, liability
Operation manual
maximus L
11
–
Flue gas recirculation: Flue gas is introduced via the path of the flue gas recirculation line
11
here and added to
the primary air. This leads to cooling of the feed grate and the combustion chamber and thus to lower stress on
the components.
Heat exchanger
Abb. 2-7: Cross section of heat exchanger
Functional components
1
Flue gas pipe connecting flange
4
Flue gas pipe
7
Ash auger heat exchanger
2
Heat exchanger
5
Ash auger burner
8
Main switch
3
Electrostatic dust collector
6
Ash container
Flue gas guide
–
The flue gas
1
from the combustion chamber flows past the heat exchanger
2
, on the electrostatic dust sepa-
rator
3
into the flue gas pipe
4
and into the chimney.
De-ashing
–
The ashes falling on the feed grate (in the burner) are transported from the transverse ash auger burner
5
into
the ash container
6
.
–
The ashes falling on electrostatic dust collector
3
are transported forward by the ash auger heat exchanger
7
into the collective ash container.